6
In normal working state, big scissors master cylinder
stop valve (Z1) is open, while slave cylinder stop valve
(F1) is closed. For small scissors, master cylinder stop
valve (Z2) is open while slave cylinder stop valve (F2) is
closed.
To level the two platforms, close the stop valve to
master cylinder (Z1/Z2) while open the stop valve to
slave cylinder (F1/F2) and then press UP button to
charge oil to slave cylinder. If two much oil charged,
press DOWN button to discharge the oil from slave
cylinder to keep the two platforms at equal height. After
level adjustment, change all stop valves back to normal
working state.
2.5 Pneumatic Diagram
Fig.5
Air cylinder
Solenoid valve
Air pressure
regulator and
filter
Pump