LAUNCH VALUE-100 A/C Service Station User’s Manual
according to the procedure described in the ROUTINE
MAINTENANCE section.
PRELIMINARY PERATINS
Check that switch (j) is set to position 0. Check that all the
machine taps are closed. Connect the machine to the electrical
supply and switch on. Check that the vacuum pump oil level indicator
shows at least one-half full. If the level is lower, add oil as explained
in the MAINTENANCE section. Check that in the top-up oil container
(e) there are at least 100 cc of the oil recommended by the
manufacturer of the vehicle A/C system. Check the level of the oil in
container (m) (< 200 cc). Check on the machine display that there
are at least 3 kg of refrigerant in the bottle. Should this not be the
case, fill the machine bottle from an external bottle of appropriate
refrigerant following the procedure described in the ROUTINE
MAINTENANCE section.
PURGE NN CNDENSALE GAS
Before every service, check if there is air into the bottle; press the
temperature bottle key (ref .T12 fig.9) and read the temperature of
the bottle. Compare the bottle pressure with the one into the table; if
the bottle pressure if higher of the pressure read on the table, pull the
ring of the security valve and bring back the bottle pressure to the
table values. Example: Bottle temperature = 20 °C, the bottle
pressure must bring back at 5,2 bar.
T P
(
) (bar)
T P
(
) (bar)
T P
(
)
(bar)
T P
(
) (bar)
T P
(
) (bar)
T P
(
) (bar)
10 3.6
10.5 3.7
11 3.8
11.5 3.8
12 3.9
12.5 4
13 4.1
13.5 4.1
14 4.2
14.5 4.3
15 4.4
15.5 4.4
16 4.5
16.5 4.6
17 4.7
17.5 4.8
18 4.9
18.5 4.9
19 5
19.5 5.1
20 5.2
20.5 5.3
21 5.4
21.5 5.5
22 5.6
22.5 5.6
23 5.7
23.5 5.8
24 5.9
24.5 6
25 6.1
25.5 6.2
26 6.3
26.5 6.4
27 6.5
27.5 6.6
28 6.7
28.5 6.8
29 6.9
29.5 7.1
30 7.2
30.5 7.3
31 7.4
31.5 7.5
32 7.6
32.5 7.7
33 7.8
33.5 8
34 8.1
34.5 8.2
35 8.3
35.5 8.4
36 8.6
36.5 8.7
37 8.8
37.5 8.9
38 9.1
38.5 9.2
39 9.3
39.5 9.5
40 9.6
40.5 9.7
41 9.9
41.5 10
42 10.2
42.5 10.3
43 10.4
43.5 10.6
44 10.7
44.5 10.9
45 11
45.5 11.2
46 11.3
46.5 11.5
47 11.6
47.5 11.8
48 12
48.5 12.1
49 12.3
49.5 12.4
50 12.6
50.5 12.8
51 12.9
51.5 13.1
52 13.3
52.5 13.4
53 13.6
53.5 13.8
54 14
54.5 14.2
Summary of Contents for VALUE-100
Page 1: ...A C Service Station VALUE 100 LAUNCH USER SMANUAL Launch Machinery Co Ltd...
Page 3: ...LAUNCH VALUE 100 A C Service Station User s Manual 1 392 89 1...
Page 4: ...LAUNCH VALUE 100 A C Service Station User s Manual 2 1 1060 500 520 80 70dB A...
Page 6: ...LAUNCH VALUE 100 A C Service Station User s Manual 4 80 A C A C R134a R134a R134a...
Page 18: ...LAUNCH VALUE 100 A C Service Station User s Manual 16 200 3 16 18 3 i 7 5 40 10 5 ENTER...
Page 20: ...LAUNCH VALUE 100 A C Service Station User s Manual 18...
Page 38: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 39: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 40: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 41: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 42: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 43: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 44: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 45: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 46: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 47: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 50: ...A C Service Station VALUE 100 LAUNCH Launch Machinery Co Ltd...