LAUNCH VALUE-100 A/C Service Station User’s Manual
FILLING THE NEW IL TANK
It is good practice to fill the oil tank whenever the oil level falls
below 100 cc in order to guarantee that there will be sufficient oil for
topping up during successive operations. Types of oil: use only
synthetic oils. Always refer to the information provided by the system
manufacturer. Procedure: Remove the tank, complete with cap, after
disconnecting the quick-connect coupling on the upper part. Unscrew
the cap and fill the tank with the correct quantity of suitable type and
grade oil for compressors. Screw the cap back on, replace the tank,
and reconnect the quick-connect coupling.
EMPTYING THE USED IL TANK
This operation must be performed whenever the oil level exceeds
200 cc. Procedure: remove the tank from its lodging and unscrew the
container (holding fixed the cap); empty the tank into a container for
used oils, Screw the container (holding fixed the cap) and replace the
container in its lodging.
SPECIAL MAINTENANCE PERATINS
CALIRATING THE ELECTRNIC SCALE
This operation should be performed when the scale values
displayed are out of line with known values. The operations listed
below must be performed with the maximum attention and care.
Always observe the precautions outlined in this section. Always place
the weights carefully on the scale plate, one at a time. Always place
the weights the center of the scale plate. Proceed as explained below
to calibrate the scale (see fig.3). Disconnect the machine from
mains supply. Procure a known reference weight (16 to 18 kg).
Remove the cover on the rear of the machine to access the machine
bottle. Close the blue and red taps on the bottle. Unscrew the bottle
lock nut (3). Separate the heating coil (i,fig7) from the bottle (do not
touch or disconnect the wires of the resistance coil).
Remove the bottle (5) from its seat, leaving the resistance around
the scale plate. Rest the bottle on a stand at least 40 cm in height.
Switch on the MACHINE. Be careful not to touch any electrical wires.
Wait at least 10 seconds. Press the + and ARROW keys
simultaneously and hold down for about 5 seconds. The value
displayed at this point will correspond to the scale zero value. Press
down lightly on the scale plate; the value should increase. If it does
not, replace the charge cell. Press the ENTER key to memorize the
Summary of Contents for VALUE-100
Page 1: ...A C Service Station VALUE 100 LAUNCH USER SMANUAL Launch Machinery Co Ltd...
Page 3: ...LAUNCH VALUE 100 A C Service Station User s Manual 1 392 89 1...
Page 4: ...LAUNCH VALUE 100 A C Service Station User s Manual 2 1 1060 500 520 80 70dB A...
Page 6: ...LAUNCH VALUE 100 A C Service Station User s Manual 4 80 A C A C R134a R134a R134a...
Page 18: ...LAUNCH VALUE 100 A C Service Station User s Manual 16 200 3 16 18 3 i 7 5 40 10 5 ENTER...
Page 20: ...LAUNCH VALUE 100 A C Service Station User s Manual 18...
Page 38: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 39: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 40: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 41: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 42: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 43: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 44: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 45: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 46: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 47: ...LAUNCH VALUE 100 A C Service Station User s Manual...
Page 50: ...A C Service Station VALUE 100 LAUNCH Launch Machinery Co Ltd...