LAUNCH
X-631/X-631+
Installation and Parts Manual Precautions for Operation
1
Precautions for Operation
z
Please read the User’s Manual and the Installation and Parts Manual carefully before operating X-631or X-631+.
z
Only the qualified technician can operate the Wheel Aligner.
z
The operator must have knowledge of computer application and basic theory of wheel alignment.
z
The power voltage of X-631/X-631+ is
AC220V±10% 50±1Hz / AC110V±10% 60±1Hz
(
It can be customized
according to the requirements of customer
)
. The 3-terminal socket must be used, and the earth terminal must be
well grounded. If the power voltage is not stable, please purchase and use AC voltage stabilizer.
z
X-631/X-631+ is operated with image sensing. Do not stop the light beam between sensors. Avoid reflection light of
the ground and direct light to the probe rod while testing.
z
Charge the probe rod for 4 hours if it is not operated for over 30 days.
z
The probe rods are precision parts of the wheel aligner. Do not plug or unplug the connecting cable when the power
is turned on. Otherwise, the built-in sensor may be broken. Special care should be taken during installation and
operation to prevent the casing from being distorted and the internal parts from being damaged.
z
Install the lift according to specifications before installing X-631/X-631+, for it is necessary to lift the vehicle when
adjusting vehicle wheels. The vehicle may need lift for two times for compensation of rim run-out. Check the lift
regularly for fixedness and levelness to ensure personal safety and correct measurement. Remove the obstacles
around the lift for convenient operation.
z
Don’t place X-631/X-631+ on a vibrated object or an oblique surface. Avoid direct sunlight and moisture.
z
Avoid splashing water on the surface of X-631, for it may cause permanent damage when entering the system.
z
The wires inside the cabinet and the probe rod sensors are connected compactly. Any disconnection may cause
damage to the sensor. Damage due to unauthorized disconnection is not covered by warranty.
z
The battery for the probe rod is the consumable goods. After finishing its span life, the user should change it in his
own charge.
z
Maintain X-631 wheel aligner periodically to ensure the accuracy of measurement.
z
Turn off the power after operation. Check all bolts and parts after maintenance, and tighten the slackened bolts and
parts in turn for safety.
z
Check the packing list before installing. Do not hesitate to contact LAUNCH or LAUNCH distributors for any
questions.