X-631 Wheel Aligner Maintenance Manual
Probe Rod Calibration
5-2
b)
Install the small calibration frame well according the installation requirements, and then adjust the lateral axle
and vertical axle level (It is required to use the probe rods for auxiliary level adjustment of the small calibration
frame).
●
Adjust the lateral axle level: Install the FL probe rod on the two ends of the lateral axle respectively (as shown
in the following figures), and then adjust the adjusting screws of the brackets to keep the lateral axle level.
Computer
interface