background image

LMW – Trade Line Owner’s Manual 

      

 

it.  Fill your tub to the overflow and if you have a pump and/or blower, operate it for 15 minutes.  Inspect the 
entire unit during and after for leaks.  Any defects that are discovered 

MUST

 be reported at this time to 

qualify for warranty coverage.  Qualified plumbers and electricians 

MUST

 be used for all tub connections to 

assure you follow local codes and acquire any permits required for the install.  NEVER LIFT the unit by any 
portion of the plumbing or stand in the unit during installation as this may cause serious damage to the unit. 

*It is 

VERY

 important that your tub is supported by its base and not the rim.   

*Take your installation measurements directly from your tub, as they may vary slightly from our literature.    
When installing the drain fitting, you will notice it protrudes below the bottom of the tub.  You will need to 
allow clearance in the sub-floor for this dimension.  Now you are ready to place your tub in its desired 
location.  Check the unit and sub-floor to ensure it is level.  If it is not, insert wood shims between the sub-
floor and support base.  Mark stud wall underneath the tub’s return lip.  Remove the unit from position and 
install a 1x stop to stud wall for lip to rest on to prevent deflection.  At this time, check to see if any wiring 
needs to be completed (see wiring instructions). 
Since a great variety of installations are possible with this bath, special framing procedures may be needed.  A 
ledge under the rim, or an apron without a ledge, may be constructed as required.  Where installation is 
planned against a wall, install the tub against the studs as indicated, adding blocking below the rim to prevent 
deflection or movement of the tub, but ensuring that the weight of the tub is not supported in any way by the 
blocking (Diagram A).  When placing the unit in a platform floor or cut out installation, the opening should be 
1” smaller than the specified rim dimensions. 
A 1” integral up-flange is available on many rectangular and corner models.  These units should be placed in a 
pre-measured studded pocket.  Pre-drill holes through the flange to align with studs.  Use screws to secure 
studs (Diagram B).  

DO NOT

 attempt to nail directly through the flange.  

Always pre-drill the holes

In every “system” installation, an access panel must be placed near the pump/blower for servicing.  This 
access may be through the wall or platform apron.  In the case of a sunken installation, access may be through 
the ceiling below the bathtub.  See 

Diagram C

 for instructions for the access panel provided on the skirted tub. 

 

 

 

 

 

 

Summary of Contents for Trade series

Page 1: ...OOLS TRADE LINE OWNER S MANUAL For your installation operation and maintenance needs Whirlpools Air Baths Combo Baths Soakers WATER TEST PRIOR TO INSTALLATION Laurel Mountain Whirlpools Service Center...

Page 2: ...urel Mountain Whirlpools tub or it s hardware will void the warranty of this product if written approval is not obtained from the manufacturer Your Laurel Mountain Whirlpools tub was created to your o...

Page 3: ...d install a 1x stop to stud wall for lip to rest on to prevent deflection At this time check to see if any wiring needs to be completed see wiring instructions Since a great variety of installations a...

Page 4: ...ccessories before installing the GFCI wall outlets Also the power supply cords equipped with each accessory are only 2 5 long so locate the GFCI wall outlet within 1 5 of the intended accessory Electr...

Page 5: ...sh and will retain its high luster for years with proper care Never use an abrasive cleaner or pad to clean your bath tub Always use a soft cloth or sponge along with a spray liquid non abrasive bath...

Page 6: ...of a supply cord Check your local codes and install a 120VAC 20amp GFCI protected dedicated circuit wall outlet within 1 5 from the heater unit Plug the cord into the outlet Every time the whirlpool...

Page 7: ...d period of time it is possible that the thermic protection has shut off the motor Allow to cool off for at least 30 minutes before further use PUMP Won t Start Motor hums Check to see if on off switc...