Laurel Mountain Whirlpools Warranty 

This Laurel Mountain Whirlpools bath is warranted to the original purchaser to be free from defects in material and 
workmanship for the following periods.  The bathtub shell, pump, heater, and blower carry a 5 year warranty.  Other 
working parts are warranted for 3 years.  Proof of purchase is required. 
This warranty is issued to the original purchaser and shall be effective from the date of purchase as shown on 
purchaser’s receipt.  Laurel Mountain Whirlpools will repair or replace (at their choice) any unit which proves to be 
defective in material or workmanship under normal use and service, having been properly installed.  This warranty is the 
only express warranty made by Laurel Mountain Whirlpools and is limited to the duration of this warranty.  Any labor 
charges and/or damage incurred in installation, repair or replacement as well as incidental and consequential damages 
connected therewith are excluded and will not be paid by Laurel Mountain Whirlpools.  Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to 
you.  This warranty is void for any damage to the bath due to abuse, misuse, neglect, accident, improper installation, any 
use violating instructions furnished by us, or repair not authorized in writing by Laurel Mountain.

 

 

WHIRLPOOL  

 

 

 

 

AIR BATH

 

PROBLEM 

SOLUTION 

PROBLEM 

SOLUTION 

ON/OFF BUTTON 

Won’t depress 

 

Remove trim ring and plunger.  Clean 
interior, lubricate with small amount of 
vasoline. 

BLOWER 

-

Fails to 

operate

 

 
 
 
 

 

-Check electric power supply.  Reset the 
circuit breaker or replace fuse if necessary.                                                      
-Check ground fault circuit interrupter.  
Reset if tripped.                                                   
-If the system has been functioning for an 
extended period of time, it is possible that 
the thermic protection has shut off the 
motor.  Allow to cool off for at least 30 
minutes before further use. 

PUMP 

-Won’t Start 

 
 
 
 
 
 
 
 

-Motor hums 

-Check to see if on/off switch or 
pneumatic switch is ON. 
-Check electric power supply.  Reset the 
circuit breaker or replace fuse if 
necessary. 
-Check ground fault circuit interrupter.  
Reset if tripped. 
-Check to see if both ends of plastic air 
switch tubes are connected.

 

Check for binding of motor shaft or 
obstruction in pump.  Manually rotate 
motor shaft to see that shaft turns freely. 
-Check to see if highest jet is clogged.  
Check to see that water is at a high 
enough level for pump to prime. 
-Check for air leak in suction line.  Slightly 
loosen pump union & then retighten by 
hand. 
-Check for obstruction in piping system. 

MOTOR 

-Runs but no 

air blown 

through jets 

Verify that the main air hose from the 
manifold to the blower is properly 
connected.  If necessary, reconnect and 
tighten clamps. 

 

JET HEAD 

AIR 

OUTLETS 

-Are 

obstructed 

 

If the air outlets of a jet head are obstructed 
by soap or other residues, fill the tub with 
warm water, then switch the system on and 
off several times.  The air outlets should be 
cleared, if this is not sufficient, carefully tap 
on the jet heads with the handle of a screw 
driver or similar tool while the blower runs. 

 

AIR 

HEATER 

-Does not 
appear to 
be working 

-Fill the tub to working level & operate 
blower on high for 5 minutes.  Carefully feel 
the flexible connection hose where it 
connects to blower.  The hose and its 
immediate area should feel warm to the 
touch, if not,call Laurel Mountain Whirlpools 

-If your tub is installed against 2 outside 
walls, adequate insulation is recommended 
to minimize heat loss. 

LEAKS 

-Pump Unions 

-Pump o-ring 

or seal 

-Pipe to Jet 

 

JET 

Low/no water 

pressure 

Loosen pump unions and inspect o-ring 
for proper sealing.  Retighten. 
 
Call Laurel Mountain Whirlpools 
customer service at 1-800-930-0050 
 
Turn the trim ring around the jet.  This 
will open/close the jet. 

 

 

Summary of Contents for Trade series

Page 1: ...OOLS TRADE LINE OWNER S MANUAL For your installation operation and maintenance needs Whirlpools Air Baths Combo Baths Soakers WATER TEST PRIOR TO INSTALLATION Laurel Mountain Whirlpools Service Center...

Page 2: ...urel Mountain Whirlpools tub or it s hardware will void the warranty of this product if written approval is not obtained from the manufacturer Your Laurel Mountain Whirlpools tub was created to your o...

Page 3: ...d install a 1x stop to stud wall for lip to rest on to prevent deflection At this time check to see if any wiring needs to be completed see wiring instructions Since a great variety of installations a...

Page 4: ...ccessories before installing the GFCI wall outlets Also the power supply cords equipped with each accessory are only 2 5 long so locate the GFCI wall outlet within 1 5 of the intended accessory Electr...

Page 5: ...sh and will retain its high luster for years with proper care Never use an abrasive cleaner or pad to clean your bath tub Always use a soft cloth or sponge along with a spray liquid non abrasive bath...

Page 6: ...of a supply cord Check your local codes and install a 120VAC 20amp GFCI protected dedicated circuit wall outlet within 1 5 from the heater unit Plug the cord into the outlet Every time the whirlpool...

Page 7: ...d period of time it is possible that the thermic protection has shut off the motor Allow to cool off for at least 30 minutes before further use PUMP Won t Start Motor hums Check to see if on off switc...

Reviews: