background image

LAUREL MOUNTAIN WHIRLPOOLS 

 

Owner’s Manual 

Page 6 

 

WARNING:  RISK OF HYPERTHERMIA AND POSSIBLE DROWNING, WATER 
TEMPERATURE IN EXCESS OF 38®C MAY BE INJURIOUS TO YOUR HEALTH.  CHECK AND 
ADJUST WATER TEMPERATURE BEFORE USE. 

WARNING:  RISK OF HYPERTHERMIA, PEOPLE USING MEDICATION AND/OR HAVING AN 
ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A 
HYDROMASSAGE BATHTUB EQUIPPED WITH HEATER. 

-For Indoor use only, Use unit only for its intended use as described in this manual. 
-Install in accordance with the Manufacturer’s Installation instructions. 
-Use supply wires suitable for 20A OC. 
-Connect only to a circuit protected by a Class A ground fault circuit interrupter. 
-Connect only to a branch circuit protected by and over current protection device 
rated not more than 20A. 
-Bonding lugs use copper conductors only. 

 

(For permanently connected units) A green-colored terminal (or a wire connector Marked “G”, 
“GR”, “Ground,” or “Grounding”) is provided within the terminal compartment.  To reduce the 
risk of electric shock, connect this terminal or connector to the grounding terminal of your 
electric service or supply panel (SEE WIRING DIAGRAM PAGE 7) with a conductor Equivalent in 
size to the circuit conductors supplying this equipment. 

Do not use attachments not recommended by the manufacturer. 

Never drop or insert any object into any opening 

Do not operate this unit without the guard over the suction fitting. 

The unit must be connected only to a supply circuit that is protected by a ground-fault Circuit-
interrupter (GFCI).  Such a GFCI should be provided by the installer and needs to be tested on 
a routine basis in ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS. 

(For permanently connected units) A green-colored terminal (or a wire connector Marked “G,” 
“GR,” “Ground,” or “Grounding”) is provided within the terminal Compartment.  To reduce 
the risk of electric shock, connect this terminal or connector to the grounding terminal of your 
electric service or supply panel with a conductor equivalent in size to the circuit conductors 
supplying this equipment. 

 
 

Summary of Contents for Walk-In

Page 1: ...Laurel Mountain Whirlpools Walk In Bathtub Owner s Manual...

Page 2: ...information Page 5 6 Operation Instructions Page 7 Drain Adjustment Instructions Page 8 Care and Maintenance Page 9 Warranty Information Page 10 Contact Information Laurel Mountain Whirlpools 1610 Jam...

Page 3: ...to use Our bath shells are fabricated from cast high quality gleaming sheets of durable acrylic The non porous surface is impervious to stains grease or grime associated with surface finishes of conve...

Page 4: ...LAUREL MOUNTAIN WHIRLPOOLS Owner s Manual Page 4...

Page 5: ...ncluding the following WARNING RISK OF ACCIDENTAL INJURY OR DROWING CHILDREN SHOULD NOT USE ANY HYDROMASSAGE BATHTUB WITHOUT ADULT SUPERVISION WARNING RISK OF ACCIDENTAL INJURY OR DROWNING DO NOT USE...

Page 6: ...ounding is provided within the terminal compartment To reduce the risk of electric shock connect this terminal or connector to the grounding terminal of your electric service or supply panel SEE WIRIN...

Page 7: ...n air mixing control knob mounted high inside the walls of the tub bowl or on the flat deck surface This controls the air that mixes with water coming out of the jets You can increase the air supply b...

Page 8: ...p 1 Lift the drain stopper out of the drain Step 2 Locate the lock nut as shown in figure 1 Step 3 Loosen the lock nut as shown in figure 2 Step 4 Turn the adjusting bolt in or out to the desired heig...

Page 9: ...g detergent along with no more than 4 ounces of a household bleach to the water Operate for 5 to 10 minutes Drain the tub fill it with water operate for 5 minutes then drain When using your whirlpool...

Page 10: ...LL AS INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH ARE EXCLUDED AND WILL NOT BE PAID BY LAUREL MOUNTAIN WHIRLPOOL Some states do not allow the exclusion or limitation of incidental or cons...