Summary of Contents for Ember

Page 1: ......

Page 2: ...e gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER WARNING WARNING For Outdoor Use Only Installer Leave this manual to the owner for future use Consumer Please keep this manual for future reference Gas Fired Outdoor Infrared Patio Heaters Quest...

Page 3: ...ntenance can cause injury death or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNINGS AND CAUTIONS SPECIFICATION Certification CSA Height 70 87 1 80 m Rated heat input 51 000 BTU hr Gas type LPG Gas Supply 20 lb 9 kg LP gas cylinder Manifold pressure 11 W C Diameter of injector 1 13 1 90 mm Safety features ...

Page 4: ...eas where the hose will not be subject to accidental damage Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is im...

Page 5: ...ontal periphery of the enclosure is permanently open This appliance requires 9kg 20lb LP gas supply cylinder The LP gas supply cylinder to be used must be Constructed and marked in accordance with the Specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Com mission CAN CSA B339 as a...

Page 6: ...PARATION Before beginning assembly of product make sure all parts are present If any part is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Perform a leak test with a soapy solution 1 To check gas connections 2 After connecting a new cylinder 3 Upon re assembly after disassembly WARNINGS AND CAUTIONS ...

Page 7: ...rface Weather resistant dome prevents water from entering the combustion zone and reflects heat down Safety guard protects the full height of the heat exchanger tube Gas control with electronic igniter is centrally positioned for easy access Integrated wheels allow for easy transport The large base ensures good stability Chimney cover Control Knob AA Battery 1 5V not included M6x12 Thumb Screw M6x...

Page 8: ...amber door Carefully lift dome until entire heat exchange tube is exposed Step 2 After heat exchange tube is fully extended rotate counter clockwise until stopped Warning This appliance requires installation by a competent person Proper assembly is the responsibility of the installer ...

Page 9: ... Remove knob from door and place on control stem Warning This appliance requires installation by a competentperson Proper assembly is the responsibility of theinstaller Step 3 Step3 Insert M6x35 thumb screw into hole A and M6x12 A B thumb screw into hole B Lock the screws ...

Page 10: ...nt person Proper assembly is the responsibility of the installer Step6 Place the gas cylinder not included into the base assembly and fix it with fixing chain Attach the regulator to the cylinder turn clockwise to tighten it securely and then close the door Note Make sure to check for leaks once the cylinder has been replaced Refer to the check for leaks section on page 10 Tighten ...

Page 11: ...on regulator cylinder connection 3 Turn on gas cylinder valve Inspect the connections and look for bubbles 4 If no bubbles appear the connection is safe 5 If bubbles appear there is leakage Loosen and re tighten this connection If connection still leaks please call customer service 1 866 814 0585 Note 1 The cylinder supply system must be arranged for vapor withdrawal 2 The cylinder used must inclu...

Page 12: ...nob and turn counter clockwise to IGNITE 3 Continue to depress knob for 30 seconds listen to ignition pulse 4 Then release knob and turn to adjust heat intensit 5 If pilot does not light turn knob to OFF and wait 5 minutes for gas vapors to dissipate then repeat steps 2 to 4 ...

Page 13: ... from the burner turn the control knob to the Minimum position Then turn the knob to the level of heat desired If you experience any ignition problem consult the following Troubleshooting These lighting instructions must be followed An unsafe condition can occur if they are not followed correctly ...

Page 14: ...OPERATION 13 ...

Page 15: ...marily used for the heating of outdoor patios decks spas pools and open working areas Always make sure that adequate fresh air ventilation is provided Follow the spacing tolerances shown in the following figure right at all times This heater must be placed on level firm ground Never operate in an explosive atmosphere Keep away from areas where gasoline or other flammable liquids or vapors are stor...

Page 16: ...trol is exposed to water in any way do NOT try to use it It must be replaced Keep the appliance area free and clean from combustible materials gasoline and other flammable vapors and liquids not obstructing the flow of combustion and ventilation air keeping the ventilation opening s of the cylinder enclosure free and clear from debris Gas odor with extreme yellow tipping of flame Heater does NOT r...

Page 17: ...eavy duty pipe cleaner Compressed air may help clear away smaller particles Carbon deposits may create a fire hazard Clean dome and engine with warm soapy water if any carbon deposits develop STORAGE Between uses During periods of extended inactivity or when transporting Turn the control knob to OFF position Disconnect the regulator from the LP Cylinder by turning counter clockwise and move to a s...

Page 18: ...TROUBLESHOOTING 17 ...

Page 19: ...purchaser only and excludes industrial commercial or business use of the product product damage due to shipment or failure which results from alteration product abuse or product misuse whether performed by a contractor service company or consumer We will not be responsible for labor charges and or damage incurred in installation repair or replace ment nor for incidental or consequential damage LAV...