9
ASSEMBLY INSTRUCTIONS
7
Standard 20 lb. tank
7. Connect hose and regulator to cylinder.
The propane gas and cylinder are sold separately.
Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal
supply system. See chapter 12 of the standard for
storage and handling of liquefied petroleum gas,
ANSI/NFPA 58 or CSA B149.1, Natural Gas and
Propane Installation Code. Your local library or fire
department should have this book.
Storage of an appliance indoors is permissible only if
the cylinder is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a
well-ventilated area out of the reach of children. A
disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage
or any other enclosed area. The maximum inlet gas
supply pressure: 250 psi, The minimum inlet gas
supply pressure: 5 psi. is required for purpose of input
adjustment. The minimum hourly of 16000 Btu/hr is
required input rating for a heater at ratings less than
full input rating. The pressure regulator and hose
assembly supplied with the appliance must be used.
The installation must conform with local codes, or in
the absence of local codes,with national fuel gas code,
ANSI Z223.1/NFPA54, natural gas and propane Instal-
lation Code, CSA B149.1, or propane storage and
handling code, B149.2.