554515_A_PUB_DATE_1_FEB_2014.DOC
INSTALLATION AND MAINTENANCE MANUAL
49
LIQUID SOAP CONNECTION
MACHINES 80-100-120 kg / 180-230-275 lb
Connection point for soap supply, see figure 3.5., pos.9.
MACHINES 33-40-55 kg / 80-100-125 lb
By default the machines are produces in version: With liquid soap
General :
Always use liquid soap pumps that have a flow rate high enough to bring the requested quantity
into the washer in less than 30 sec.
Important :
Start pumping immediately after the water valves are open. The incoming water dilutes the liquid
soap and brings it into the tub assembly.
Caution :
Secure the location of the wiring and hoses in such a way that they can not be pinched, damaged
or rubbed. Only authorized workers, with a valid qualification, should do the installation.
Before you start to use liquid soap, check with your liquid soap supplier whether the liquid soap
is harmless and inert to HD-PE and PVC material in order to avoid a problem that manufacturer
is not responsible for.
MACHINES 33-40-55 kg / 80-100-125 lb
The washer has provisions for connecting external dosing of liquid soaps. On the back side, a plastic hose
connection part is present, figure 4.4.F to connect the liquid soap hoses. Depending of the number of liquid
soap pumps that will be used, drill holes (max. 5) of Ø 8 mm / 0.315“ in the plastic hose connection part for
each pump. On the plastic hose connection part is also a nipple of Ø 12 mm / ½“. Use this nipple
ONLY
for
entering diluted soap. Drill with Ø 11.5 mm / 0.45“. By default, these nipples are closed. Drill only the ones
that will be used.
Take care that the drill particles are carefully removed so that they can not clog up the hoses and openings.
WARNING!
CHECK THAT THE HOSE CONNECTIONS ARE TIGHT (CHECK THE CLAMPS)! ANY LEAKAGE
OF CHEMICALS MAY CAUSE SERIOUS BODILY INJURIES AS WELL AS SERIOUS DAMAGE
TO THE WASHER.
IF ONE OF THE NIPPLES ARE OPEN, CLOSE AND SECURE THE OPENING WITH AN APPROPRIATE COVER.
ELECTRICAL CONNECTION
The power supply of the liquid soap pump system has to be connected to an external electrical source. Only
authorized workers with a valid qualification must execute the electrical connection on the machine according
to the valid local standards. The correct connection way can be found on the wiring diagram that is located
inside the cabinet in a plastic bag. Do not connect the liquid soap pump system in the washer.
!
Figure 4.4.G – Machines 80-100-120 kg /
180-230-275 lb, hose connection
Figure 4.4.F – Machines 33-40-55 kg / 80-100-125 lb
Plastic hose connection part
Summary of Contents for LH-1000
Page 2: ......