Page 4: ...hold the icon The word HOLD will start blinking and after a few seconds a double chime will sound when the temperature has stabilized The stabilized temperature remain on the display as long as you are holding the icon Release your finger to return to normal ...

Page 5: ...MAX MIN Double tap the icon to display the maximum temperature for current session Tap again for the minimum temperature To exit tap again Hold the icon during MAX MIN to clear values ...

Page 6: ...POWER SAVER Hold the icon to enable power saving mode This will disable the backlight and reduce power consumption Press and hold the icon again to exit this feature ...

Page 7: ...obe and twist open the battery door with a coin Carefully remove existing battery and insert a new CR2032 with the positive pole up MODEL PX1 LAVATOOLS CALIFORNIA Assembled in China MEASURING RANGE 40 F 482 F 40 C 250 C TOUCH SENSOR Single tap for backlight Double tap for MIN MAX Hold for Stabilization Alert C R 2 0 3 2 ...

Page 8: ...O will automatically go to sleep Simply tap the touch pad to wake the device Antifog Display The display is coated in a hydrophobic agent to keep the readout fog free even when measuring steaming liquids For this reason we do not recommend scouring cleaning products as it will strip the coating ...

Page 9: ...tainless steel surfaces Antimicrobial Coating Silver based antimicrobial additive is impregnated into the plastic shell to inhibit the growth of pathogens Efficacy is rated at 99 or greater Tapered Sensor Tip The ultra sensitive thermistor sensor is located at the tip of the probe requiring a minimum insertion distance of 0 25 5mm ...

Page 10: ...RO using switches found inside the battery bay You can disable and re enable various functions by toggling their respective switches You must turn off the device to have these changes apply toggle C F toggle auto off toggle stabilization alert ...

Page 11: ... large cup with crushed ice Next fill 3 4 of the cup with purified water Let the slurry sit for a brief moment and give it a quick stir to allow the temperature to equalize throughout Insert the tip of the probe into the very center of the cup and stir gently In 3 to 4 seconds the display will read within 1 F 0 5 C of 32 F 0 C ...

Page 12: ...act and extend probe or change battery NO BACKLIGHT ensure battery saving mode is disabled DISPLAYING ERROR battery is running low change batteries CHANGE C F use switch 1 to switch between C F see page 10 TROUBLESHOOTING ...

Page 13: ...evice RESTORE FACTORY SETTINGS turn off device and position all personalization switches downwards DON T HEAR DOUBLE CHIME make sure to hold the touch pad long enough HOLD DOESN T BLINK use switch 3 to activate stabilization alert see page 10 ...

Page 14: ...down the probe after each use Clean the body with soft damp cloth Do not use solvents or scouring agents Do not put the device in the dishwasher This device is exclusively intended for the field of application described in this manual It should only be used as described within these instructions Abuse water damage modification or accidental breakage to the product will void all warranty ...

Page 15: ...ly over fire Never immerse the device in liquid for any period of time Keep the device and battery out of reach of children Do not subject the device to extreme temperature vibration or shock Batteries must not be thrown into the fire short circuited taken apart or recharged ...