PROBLEM
CAUSE
SOLUTION
Water leaks from the machine.
The drain tray does not discharge.
Check the sewer drain.
The drain pipe is broken or detached or
clogged.
Check and restore the connection of
the drain pipe to the drain tray.
Water leaks in the hydraulic circuit.
Check and eliminate any hydraulic
leaks.
Coffee is cold.
The heating element is damaged.
Replace the electrical heating ele-
ment.
The electrical connection is defective.
Check for possible defects on the
connection.
Lime scale on the exchangers and/or the
heating element.
Clean the machine.
The thermostat to protect the heating ele-
ment is trigged.
Reset the heating element protection.
Lime scale has reduced the water circu-
lation.
Clean the connectors of the exchan-
ger, clean or replace the two circula-
tion pipes.
The brewing unit is cold.
Eliminate air pockets in the hydraulic
circuit as follows:
- electrically disconnect the pump
- close the water tap of the softener
- dry running the machine for a few
minutes
- electrically connect the pump again
- open the water mains valve
- carry out brewing until the water
comes out
- wait a few minutes for heating.
Manual code 10066574 / Rel. 2.00 / February 2012
23
Maintenance manual for technical assistance