PROBLEM
CAUSE
SOLUTION
Coffee is too hot.
The boiler temperature is too high.
Reduce the temperature in the boiler.
The flow reducer of the brewing unit is
not suitable.
Replace the reducer with one of a
smaller diameter.
Coffee is dispensed too quickly.
The diameter of the injector is too large. Replace the injector with one of a
smaller diameter.
The boiler temperature is too high.
Reduce the temperature in the boiler.
Coffee is dispensed too slowly.
The injector of the brewing unit is clog-
ged.
Replace the brewing unit injector.
The brewing unit is clogged.
Controllare e pulire il gruppo eroga-
zione.
The capsule-holder is dirty.
Check and clean the brewing unit.
Lower perforators are dirty.
Clean and replace the perforators, if
necessary.
The pressure gauge indicates an
unacceptable pressure.
The pressure gauge is defective.
Replace the pressure gauge.
The boiler calibration is incorrect.
Adjust the calibration of the boiler.
Grounds in cup.
The capsule-holder is dirty.
Clean the capsule-holder.
The lower perforator holes are worn.
Replace the lower perforator.
The internal gasket is worn.
Reduce the boiler temperature.
The temperature of the dispensed water
is high.
Replace the reducer with one of a
smaller diameter.
24
Manual code 10066574 / Rel. 2.00 / February 2012
Maintenance manual for technical assistance