6600-NG User’s Manual
125-9110A
Page 23
There are additional parameters displayed on Main Operating screen, as shown in Fig. 3.2 below. These
are described in detail below.
Figure 3.2 : Main operating screen (remaining details)
[17]
Ps2 units
The selected Ps2 units are displayed here. There are 14 different Pt units available.
1. inHg
5. psi
9. kpa
13. knots
2. Diff. inHg
6. Diff. psi
10. Diff. kpa
14. km/hr
3. mbar
7. mmHg
11. Feet
4. Diff. mbar
8. Diff. mmHg
12. Meters
Note: Diff. units (including knots and km/hr) display differential pressure with respect to Ps1 pressure.
Remaining units display absolute Ps2 pressure.
Selecting the desired Ps2 units is described in Section 3.xx.
[18]
Ps2 Actual value
The Actual value (actual pressure converted to selected units) being measured or controlled at the Ps2
output is displayed here in the selected Ps2 units. The displayed resolution of this value depends on the
selected units and is shown in the table below. This Actual value is updated every 250 msec.
29.9213
30.0000
Pt inHg
Pt
Ps2
Ps1
Measure
inHg/min
0.000
4.000
inHg
inHg
29.9213
29.9213
Pt inHg
30.0000
30.0000
inHg/min
inHg/min
0.000
0.000
4.000
4.000
Measure
Measure
1
2
3
4
9
0
.
±
6
7
8
5
AC
92%
Hide/Show Ps2
000
Messages
17
18
19
20
21
22
24
23
25
29
27
26
28