background image

Superabrasive 

Owner’s Manual Original Language – Lavina 

®

 LA2000-115 

01/2019 

 

8

 

 
 
 
 
 
SAFETY PRECAUTIONS, Continued 
• 

Superabrasive 

cannot 

predict 

all 

possible 

circumstances  that  could  present  a  potential  hazard.  
The  warnings  defined  in  this  manual  should  not  be 
considered  completely  inclusive  of  all  hazardous 
situations. 
•  It  is  the  responsibility  of  the  employer  or  air  cleaner 
owner  to  train  any  personnel  that  will  be  operating  the 
air  cleaner,  while  complying  with  all  local  laws  and 
regulations.  
•  This  specific  air  cleaner  has  been  designed  for  
collection  of  dusts.    This model  is  not  intended  for  any 
other  uses  or  applications.  •  IMPORTANT:    Only  use 
specified  filters  applicable  to  the  operation  of  this  dust 
collector. 
• To ensure efficient operation of the the air cleaner, it 
must  be  protected  from  extreme  environmental 
conditions and elements.  This may include rain, snow, 
hail, and airborne debris. 
•  The  dust  collector  should  only  be  operated  in 
environments  with  a  temperature  between  41°F  and 
113°F  (5°C  to  45°C)  and  a maximum  relative  humidity 
of 70%.  
•  The  work  environment  for  the  air  cleaner  should  be 
well-lit, and free of combustible elements. 
•  Before  the  air  cleaner  is  connected  to  the  power 
source, ensure that the electrical voltage and frequency 
is correct for your specific machine model. 
•  The  air  cleaner  should  not  be  operated  without  the 
proper  filters  installed.    This  could  possibly  result  in 
damage  to  the  machine,  and  cause  harm  to 
surrounding personnel.  
•  Do  not  change  the  filters  assembly  while  the  air 
cleaner is operating.  
 
 

 
 
 
 
 
•  If  toxic  or  harmful  substances  accidentally  enter  the 
air  cleaner,  the  filters  must  be  removed  immediately 
using  the  proper  protective  equipment  and  safety 
procedures. 
•  When  performing  any  type  of  maintenance 
procedures  on  the  air  cleaner,  be  sure  that  the  power 
switches  are  turned  off  and  the  power  cable  is 
disconnected  from  the  power  source.    Utilize  the 
locking caster wheels sto prevent movement while work 
is being performed. 
• Make sure the power cable is free from damage while 
operating the air cleaner. If the power cable is found to 
be  damaged,  discontinue  use  of  the  air  cleaner      and 
replace the power cable immediately.  
• When moving the air cleaner, never pull on the power 
cable  or  hose.      For  this  purpose,  always  use  the 
designated handles mounted on the machine.  
• For this specific air cleaner, sound tests indicate that 
the emitted noise is level is measured at a maximum of 
67  decibels  (dBA),  for  a  distance  of  1  meter  from  the 
machine (and height of 1.60 meters).   
•  CAUTION:    The  National  Institute  for  Occupational 
Safety and Health (NIOSH) recommends that exposure 
to  noise  in  the  working  environment  be  maintained 
below a level equivalent to 85 dBA for a period of eight 
hours,  in  order  to  minimize  occupational,  noiseinduced 
hearing  loss.    Any  persons  working  in  proximity  of  the 
vacuum  cleaner  should  wear  the  proper  hearing 
protection in order to prevent hearing loss.  Please refer 
to you local laws and regulations for further information 
on the matter.  
•  When  storing  the  air  cleaner,  the  filters  should  be 
removed  and  cleaned.    Store  the  vacuum  in 
temperatures between 32°F and 104°F (0°C and 40°C).  
Cover  the  air  cleaner  in  order  to  protect  it  from  
accumulating  debris  and/  or  environmental  elements.                                                               

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for LA2000-115

Page 1: ...LAVINA LA2000 115 Air scrubber User Manual Tech Support Line 800 987 8403 www superabrasive com info superabrasive us...

Page 2: ...Superabrasive Owner s Manual Original Language Lavina LA2000 115 01 2019 2...

Page 3: ...ment All warranty returns must be shipped freight prepaid This warranty is in lieu of and excludes every condition of warranty not herein expressly set out and all liability for any form of consequent...

Page 4: ...fo superabrasive us Tel 706 658 1122 Fax 706 658 0357 Website www superabrasive com Table of Contents 1 WARRANTY AND RETURNS 3 WARRANTY POLICY FOR LAVINA LA2000 115 3 RETURN POLICY FOR LAVINA LA2000 1...

Page 5: ...enable them to work more efficiently General Description The air cleaner Lavina LA2000 115 is designed for sucking and separating dry non combustible non explosive dust Air and finer particles then pa...

Page 6: ...d HP 0 8 HP Speed rmp 1680 1350 rmp Amperage Amps 4 8 3 6 Amps Max 12 Amps IP 22 Pre Filter area m 2 0 64 m 2 ft 2 6 89 ft 2 Hepa filter area m 2 10 5 m 2 ft 2 113 ft 2 Hepa Filter classification H13...

Page 7: ...ing normal operating and maintenance cycles the operator is exposed to some residual risks which cannot be eliminated due to the nature of machine operation BEFORE YOU BEGIN A first time operator must...

Page 8: ...is operating If toxic or harmful substances accidentally enter the air cleaner the filters must be removed immediately using the proper protective equipment and safety procedures When performing any...

Page 9: ...damage or injury The wheels should be locked on uneven surfaces to prevent unexpected rolling or movement To lock or unlock the caster wheels follow the procedure shown below To lock the caster wheels...

Page 10: ...d place it gently in a plastic bag This bag must be properly disposed of Insert a new filter CAUTION If you are removing the filters in order to clean them hitting the filter with force or use of comp...

Page 11: ...oper protective equipment clothing eye protection and or gloves In order to ensure safe and efficient operation of the air scrubber the following procedures should be performed periodically depending...

Page 12: ...IVE ACTION THE FAN DOES NOT START NO POWER CABLE DEFECTIVE SWITCH DEFECTIVE CONNECT THE MACHINE CHANGE CHANGE THE FAN STOPS IMMEDIATELY WRONG FUSE CONNECT THE CORRECT FUSE THE FAN RUNS BUT SUCTION IS...

Page 13: ...Superabrasive Owner s Manual Original Language Lavina LA2000 115 01 2019 13 13 LAVINA LA2000 115 GENERAL PARTS...

Page 14: ...2000 115 60 00 00 Backside plate 1 10 30311000816 Red lamp 1 11 30313000151 Counter electro mechanical 1 12 30311000815 Yellow lamp 1 13 30311000538 Fuse holder 1 14 30311000536 Fuse 1 15 30312000058...