8. SAFETY PRECAUTIONS 

  
RECOM

MENDED  USE      The  LAVINA®  LA2000-230  

Air cleaner  is designed and manufactured  for dry use 
only. 

 

For 

more 

information, 

please 

contact 

Superabrasive. 
PROHIBITED  USE      The  air  cleaner  MUST  NOT  be 
used

: • For applications apart from those stated in this 

manual  
•  For  non-suitable  materials  (e.g.  asbestos  or  other 
toxic materials)  
•  In  environments  which  (1)  Possess  the  risk  of 
explosion,  (2)  Possess  high  concentration  of  powders 
or oil substances in the air, (3) Possess the risk of fire, 
(4) 

Feature 

inclement  conditions, 

(5) 

Possess 

electromagnetic radiation  
• The air cleaner should be not connected to electrical 
power when performing maintenance-related tasks 
PREPARATION FOR WORK  
Ensure that: 
•  You  have  closed  the  work  area,  so  that  no  person 
unfamiliar  with  operating  the  air  cleaner  can  enter  the 
area • There are no missing parts on your machine  
• The machine is in an upright, working position  
• All protection devices are working properly 
• The electrical cable is free to move and follow the air 
cleaner  easily.    In  order  to  keep  the  electrical  cable 
from  being  damaged,  no  vehicle  should  enter  the  area 
where electrical cables are present. 
ARREST  FUNCTIONS      Functions  for  arresting  of  the 
air cleaner include following: 
 

• Button to stop the motor 

SAFE USE    The LAVINA®  LA2000-230  is designed 
to  eliminate  all  potential  risks  associated  with  its  use.  
However,  accidents  may  occur  if  unskilled  or 
uninstructed  workers  fail  to  heed  the  list  of  potential 
risks below:  
•  Position  Risks  due  to  operator’s  incorrect  working 
position  
 

• Tangling Risks due to wearing inappropriate working 

clothes  
• Training Risks due to lack of operational training 
NOTE: Machine operators should follow the instructions 
in the manual at all times. 
RESIDUAL  RISKS    During  normal  operating  and 
maintenance cycles, the operator is exposed to some  
 
 

 
 
residual  risks,  which  cannot  be  eliminated  due  to  the 
nature of machine operation. 
BEFORE YOU BEGIN  
• A first-time operator must always read the manual and 
heed all safety instructions.  
• All electric connections and cables must be inspected 
for potential damage.  
• Ground wire system of the power supply must be also 
inspected. 
 

•  Perform  general  daily  inspections  of  the  air  cleaner 

and inspect the air cleaner before each use for any sign 
of damage.  
• Inspect all safety devices. 
 

•  The  air  cleaner  /filters  must  be  clean  and  the  hose 

should be connected. 
OPERATING  THE  MACHINE      When  operating  the 
LAVINA®  LA2000-230,  be  sure  that  no  one  else  is 
within  close  proximity  to  the  air  cleaner.    Never  leave 
the  air  cleaner    unattended  while  working.    The 
electrical  cable  and  hose  must  move  freely,  be 
damage-free,  and  should  never  run  beneath  the  air 
cleaner .   
AFTER WORK IS COMPLETED 
When  work  is  complete,  clean  the  air  cleaner  and  its 
surroundings  sufficiently,  unplug  the  air  cleaner  and 
wind up the electrical cable, secure the hose, and store 
the air cleaner  in a safe and secure place. 
THE  WORK  AREA    Ensure  that  the  area  is  free  of 
unauthorized  people  or  vehicles,  secure  all  cables  and 
hoses,  and  always  check  the  floor  for  debris. 
PERSONAL 

PROTECTIVE 

EQUIPMENT 

(PPE)     

When  operating  the  air  cleaner,  always  wear  safety 
shoes,  ear  protectors,  safety  gloves,  breathing  mask 
(protection  class  FFP3  -  especially  when  changing 
filters),  and  suitable  clothing.    All  persons  within  the 
immediate working area must wear safety glasses with 
side shields. 
OPERATOR    The  operator  must  be  aware  of  the 
mahin’s  work  environment,  be  properly  trained  prior  to 
operating  the  equipment,  and  fully  understand  this 
manual.      The  operator  must  understand  and  interpret 
all the drawings and designs in manual, understand  all 
sanitation  and  safety  regulations  pertaining  to  its 
operation,  know  how  to  perform  in  an  emergency 
situation,  and  have  an  adequate  technical  knowledge 
and preparation. 

Summary of Contents for LA2000-230

Page 1: ...LAVINA LA2000 230 Air scrubber User Manual www superabrasive com factory superabrasive com...

Page 2: ...by Superabrasive Superabrasive reserves the right to inspect and make a final decision on any machine returned under this warranty This warranty applies to new used and demo machines Superabrasive do...

Page 3: ...rt of the machine s technical information and can be provided upon request The vacuum unit machine is delivered with the CE mark exposed and is provided with a EC declaration of conformity Table of Co...

Page 4: ...enable them to work more efficiently General Description The air cleaner Lavina LA2000 230 is designed for sucking and separating dry non combustible non explosive dust Air and finer particles then pa...

Page 5: ...speed HP 0 7 HP Speed rmp 1380 rmp Amperage Amps 2 3 Amps Max 7 5 Amps IP 22 Pre Filter area m 2 0 64 m 2 ft 2 6 89 ft 2 Hepa filter area m 2 10 5 m 2 ft 2 113 ft 2 Hepa Filter classification H13 Sou...

Page 6: ...ing normal operating and maintenance cycles the operator is exposed to some residual risks which cannot be eliminated due to the nature of machine operation BEFORE YOU BEGIN A first time operator must...

Page 7: ...is operating If toxic or harmful substances accidentally enter the air cleaner the filters must be removed immediately using the proper protective equipment and safety procedures When performing any...

Page 8: ...damage or injury The wheels should be locked on uneven surfaces to prevent unexpected rolling or movement To lock or unlock the caster wheels follow the procedure shown below To lock the caster wheels...

Page 9: ...t gently in a plastic bag This bag must be properly disposed of Insert a new filter CAUTION If you are removing the filters in order to clean them hitting the filter with force or use of compressed ai...

Page 10: ...oper protective equipment clothing eye protection and or gloves In order to ensure safe and efficient operation of the air scrubber the following procedures should be performed periodically depending...

Page 11: ...IVE ACTION THE FAN DOES NOT START NO POWER CABLE DEFECTIVE SWITCH DEFECTIVE CONNECT THE MACHINE CHANGE CHANGE THE FAN STOPS IMMEDIATELY WRONG FUSE CONNECT THE CORRECT FUSE THE FAN RUNS BUT SUCTION IS...

Page 12: ...Superabrasive Owner s Manual Original Language Lavina LA2000 230 01 2019 12 13 LAVINA LA2000 230 GENERAL PARTS...

Page 13: ...00 03 Beam support 1 9 LA2000 115 60 00 00 Backside plate 1 10 30311000816 Red lamp 1 11 30313000152 Counter electro mechanical 1 12 30311000815 Yellow lamp 1 13 30311000538 Fuse holder 1 14 303110005...

Reviews: