Lavit Document: TM170915-‐A
15
side door properly closes.
14.
Turn on the water supply. Turn the power switch to ON at the rear of the dispenser.
The dispenser is now “live” and proper safety precautions should be
followed if any panels are removed from the unit.
15.
The dispenser will self-‐check on every power up and if OK will go to the LCD home screen
and the Lavit Button halo will be red.
16.
TO FILL THE DISPENSER WITH WATER, PUSH THE LAVIT BUTTON AND THE
DISPENSER WILL START TO FILL.
The screen will display a WATER TANK FILLING
SCREEN.
17.
When the water tanks are half filled, the compressor will turn on and start to chill. The soda
pump will also turn on when the water tank is half full. The HOME screen will appear.
18.
When the HOME screen appears turn the CO
2
gas pressure on.
SET THE REGULATOR TO
3.5 BAR OF PRESSURE BY ROTATING THE KNOB CLOCKWISE. 3.5 BAR OF PRESSURE
(50 PSI) IS INDICATED AT THE BEGINNING OF THE RED SCALE ON THE REGULATOR.
The soda tank will fill with CO
2
gas.
19.
Purge any air from the system by toggling the CO
2
Purge Valve located in the rear of the
unit. Purge gas about 3 times for 2 seconds each time.
Summary of Contents for LCB 100
Page 1: ...Lavit Document TM170915 A September 20 2015 Technical Manual Lavit LCB 100 Dispenser...
Page 4: ...Lavit Document TM170915 A 4 Section 1 The Lavit Beverage Dispenser Overview...
Page 52: ...Lavit Document TM170915 A 52 Appendix A Flow Diagram...
Page 53: ...Lavit Document TM170915 A 53 Appendix B Electrical Schematic 1...
Page 54: ...Lavit Document TM170915 A 54 Appendix C Electrical Schematic 2...
Page 55: ...Lavit Document TM170915 A 55 Appendix D Exploded Parts Detail...
Page 56: ...Lavit Document TM170915 A 56...
Page 57: ...Lavit Document TM170915 A 57 Appendix D Exploded Wetted Parts Detail...
Page 58: ...Lavit Document TM170915 A 58...