Lavit Document: TM170915-‐A
21
screen.
20.
From the Date/Time Screen, enter the Service Menu by pressing the Service Setup icon.
21.
From the Service Menu select and make the following choices:
Enter MAX TEMP and DISABLE (when disabled the icon will read “Enable”).
Set the Filter Timer to DISABLE (when Disabled the icon will read “Enable”). Filter life is
not tracked for Bottled Water installations.
Enable or Disable Sleep Mode.
Select WATER SETUP and display the water calibration screen. Calibrate the three
water streams (mix, still and sparkling) by following the Water Calibration
Procedure found at the end of this Section 2, Page 25.
22.
After completing the water calibration return to the HOME screen by pressing the Return
Arrow in the upper left of the touchscreen to back out of all service screens.
23.
Check for CO
2
leaks, check for water leaks.
24.
The dispenser should now be ready to use after the dispenser reaches temperature. The
first cooling cycle will take approximately 70 minutes.
25.
Enable and set the MAX TEMP if so desired to ensure that every beverage is served chilled.
It is recommended that this feature is Disabled unless a user has asked for colder
beverages.
26.
Should the 5 gallon bottle run out of water then the Lavit pump kit will sound an alarm and
the reset button will turn from green to red. Change the bottle and press the reset button.
Failure to change the bottle could result in a dry vend on a capsule beverage.
Summary of Contents for LCB 100
Page 1: ...Lavit Document TM170915 A September 20 2015 Technical Manual Lavit LCB 100 Dispenser...
Page 4: ...Lavit Document TM170915 A 4 Section 1 The Lavit Beverage Dispenser Overview...
Page 52: ...Lavit Document TM170915 A 52 Appendix A Flow Diagram...
Page 53: ...Lavit Document TM170915 A 53 Appendix B Electrical Schematic 1...
Page 54: ...Lavit Document TM170915 A 54 Appendix C Electrical Schematic 2...
Page 55: ...Lavit Document TM170915 A 55 Appendix D Exploded Parts Detail...
Page 56: ...Lavit Document TM170915 A 56...
Page 57: ...Lavit Document TM170915 A 57 Appendix D Exploded Wetted Parts Detail...
Page 58: ...Lavit Document TM170915 A 58...