background image

INSTALLATION 

The 

CleanJet

 should be installed where it is easily connected to the water supply. 

Before mounting, check that all valves can be easily operated and exposed surfaces are accessible for cleaning 
and routine maintenance.  

Positioning and drilling plans: 

Remove the 

CleanJet

 from the box and remove the cover by removing 

the screws at the top and pressing the release tabs. You can now access 
to the mounting holes (located on the rear panel). Mount the 

CleanJet

 on 

the wall using the supplied anchors, screws and washers.  
The versatility of the 

CleanJet

 allows the hose bracket to be installed as 

an integrated part of the unit or mounted independently as pictured 
below. 

Figure 2 – Drilling plans and positioning 

GROUND

 

700 mm (27,

56’’) 

 

700 mm (27,

56’’) 

248.9 mm 

(9,

 

8’’) 

177.8 mm 

(7,

 

0’’) 

 

198.1 mm 

(7,

8’’) 

78.7 mm 

(3,

1’’) 

PACKAGE CONTENTS: 

1.

CleanJet System

2.

Suction hose 1.83m / 6ft (1 roll for each product)

3.

Hose bracket

4.

Complete installation kit:
- Water inlet elbow fitting ¾” GHT
- Plastic hose clamps (2 for each product)
- 15 metering tips (1 bag for each product)
- 4 ultra-lean tips (1 bag for each product)
- Foot valve (1 for each product)
- Ceramic weight (1 for each product)
- Suction elbow (1 for each product)
- Wall anchors (3 pcs)
- Screws (3 pcs)
- Washers (3 pcs)

Summary of Contents for CLEANJET

Page 1: ...Rev AA 122020 1 CLEANJET SPRAYER FOAMER...

Page 2: ...Check that the detergent used is compatible with polypropylene Install the station near as possible to a water supply connection point Mount the CleanJet considering easy access for cleaning and routi...

Page 3: ...ews and washers The versatility of the CleanJet allows the hose bracket to be installed as an integrated part of the unit or mounted independently as pictured below Figure 2 Drilling plans and positio...

Page 4: ...the top of the product container using a 3 8 drill bit 5 Slide the cap ceramic weight onto the bootom of the supplied product pick up tube Connect to the foot valve as in figure above 6 Connect the p...

Page 5: ...ry hose of 15 24 m 50 ft The values in the table should be considered only as a reference as they are dependent on many variables such as water flow rate pressure chemical viscosity temperature of the...

Page 6: ...2 Select the desired cleaning phase Selector facing up OFF Selector facing right PRODUCT N 1 Selector facing down RINSE Selector facing left PRODUCT N 2 3 Activate the spray gun 4 Shut off the water...

Page 7: ...lter The calibration nozzle is clogged Clean or replace the nozzle Insufficient water pressure A minimum pressure of 22PSI is required for correct operation if the pressure is not correct contact a pl...

Page 8: ...Buyer s claim Defects that do not impair service shall not be a cause for rejection or recovery under any warranty Buyer assumes full responsibility for the use and application of the product Buyer ac...