Rev B 92818 Page | 3
MiniWash 100
—
Quick Start Guide
Changing access code
•
Enter the programming mode.
•
Press the
▲
key until the display shows
“
o+old access
code
”.
•
Press the PRG key the display shows
“
n+old access
code
”
and the red display
’
s first digit begins to blink.
•
Press the
▲
key until the blinking digit displays the de-
sired value.
•
Press the PRG key. The next digit blinks.
•
Press the
▲
key until the blinking digit displays the de-
sired value.
•
Press the PRG key. The next digit blinks.
•
Press the
▲
key until the blinking digit displays the de-
sired value.
•
Press the PRG key. All of the display
’
s digits stop blink-
ing.
•
To save the settings, while none of the display
’
s digits
are blinking, scroll the menu using the
▲
key until
“
Hld
”
appears on the display and then press PRG key. The
pump returns to standby mode and
“
on
”
appears on the
display.
Menu 1,2,3: Manually set the pump time, delay, and
lockout times.
•
Enter the programming mode.
•
Press the
▲
key to select the menu.
•
Press the PRG key to scroll between digits.
•
Press the
▲
key to change the value.
•
The maximum value is 999.
•
Press the PRG key. All of the display
’
s digits will stop
blinking.
•
To save the settings, make sure none of the display
’
s
digits are blinking, scroll the menu using the
▲
key
until
“
Hld
”
appears on the display and then press PRG
key. The pump returns to standby mode and
“
on
”
ap-
pears on the display.
Menu 4: Selecting the voltage tolerance.
•
Press the PRG and
▲
key to set your tolerance.
•
LO = 20
-
240VAC; HI = 70
-
240VAC
Menu 5: Calibrate using volume
•
Enter the programming mode.
•
Press the
▲
key until the display shows
“5
CAL
”.
•
Press the PRG key, CAL begins blinking.
•
While holding a measuring cup or flask under the
output of the pump, press the
▲
key and release
when the pump starts (display starts counting). Let
the pump run until desired amount of chemical is
dispensed then press the
▲
key again to stop.
(display shows the dosing time). The OPL Mini run
time is now programmed. Repeat these steps if new
volume is required.
•
Press the PRG key the display shows
“5
CAL
”.
•
To save the settings, scroll the menu using the
▲
key until
“
Hld
”
appears on the display and then press
PRG key. The pump returns to standby mode and
“
sby
”
appears on the display.
When finished programming, move the switch back to
the
“
ON
”
position.
Getting Started:
When the pump is powered, the display shows ON. Flip the switch on the bottom to
“
OFF
”
to enter
programming mode. The display will show
“
SBY
”.
The dosing and delay times are 0
-
999 seconds, the lock
-
out time is
0
-
999 minutes.
1. Accessing the menus
•
Move the switch to
“
OFF
”.
SBY will display.
•
Press the PRG key until the display shows
“
P
---
”.
•
Use the PRG to scroll between values. Use the
▲
to
change the number. The default is 000.
•
Press the
▲
and PRG key to enter your access code.
The default is 000.
•
The maximum value is 999.
•
The first menu will show a green 1 on the left.
Menu Structure: Indicated by the green number on the
left.
O: old access code
n: new access code
1: Delay Time
2: Pump Time
3: Lockout Time
4: Setting voltage tolerance
5: Calibration
Hld: save program using PRG key
Esc: Leave the menus