6. Installation
6.2.2
Preparation
Unpacking
The Compact Engine is delivered in its own box with all included accessories. If you have ordered a 12V DC
power supply, then this will be delivered separately.
Please check the contents of the shipping boxes, and in the event of any transport damage, contact your local
Lawo representative or email
. A list of serial numbers for all components is included with the
shipment. Please keep this list for your records.
Rack-Mounting
The Compact Engine can be mounted either in a 19-inch equipment rack or on a table top.
For table-top mounting, the unit should be laid on a flat, horizontal surface.
For rack-mounting, please install supporting slide bars to hold the weight of the unit. Please check that airflow
through the device is still possible, and use the locking devices provided. For recessed rack-mounting, use
standard, third-party, 1RU recessed rack adapters such as the ones shown below. When fitting the rack
adapters and slide bars, you must make sure that there is sufficient airflow through the device for cooling.
Front View
Rear View
Recessed Rack
Adapters
Connectors are located at the front and rear of the unit. Therefore, when using 19-inch racks with doors please
leave enough room for the cables.
Dimensions and Weight
Width
19” / 482.6 mm
Height (enclosure only)
Height (overall, incl. pads)
44.0 mm (1 RU)
46.5 mm
Depth (inc locking devices)
414 mm
Weight of frame (without expansion cards)
3.0 Kg
Temperature and Cooling
The Compact Engine is equipped with two fans inside. Ventilation holes are provided on the left and right. There
must be sufficient airflow around the device for cooling.
DO NOT
obstruct the side ventilation holes as to do so will prevent efficient cooling.
Proper operation is guaranteed between temperatures of 10° C and 35° C and a maximum relative humidity of
85%.
Power Consumption & Electrical Voltage
Please refer to the Compact Engine