16. Connecting a VisTool MK2 PC
Access Group
This option assigns an Access Group to the element. Access Groups are supported by Power
Core Max to link the control surface ACCESS keys to different VisTool instances. Any Fader
Modules set to a matching Access Group will respond to the corresponding VispageSwitch
functions.
Default Page
This page appears on the VisTool screen following a
of the remote system.
You should enter the number which corresponds to the page index within the VisTool Editor
configuration.
Clear Rights on Start
If checked, defined user rights are reset after a warm start (e.g. a power cycle). If not checked,
user rights will remain intact.
Note that you must be using VisTool MK2 to support the
system.
Load PC Snap
When this control signal is active, a window opens on the VisTool screen to load a snapshot.
Save PC Snap
As above, but to save a snapshot.
Delete PC Snap
As above, but to delete a snapshot.
Save PC Source Snap
As above, but to save a source snapshot.
PC Log-In
When this control signal is active, the user
window opens on the VisTool screen. You
must activate this function to provide access to the user rights supported by VisTool MK2.
The function should only be active on a single VisTool screen - i.e. for one VispageSwitch
element mapped to one Station Id.
PC Log-Out
As above, but the control signal logouts the current user.
Edit PC Labels
When this control signal is active, the
edit window opens on the VisTool screen.
Application Full Screen
Sets the application to full screen view.
Application WindowPos
Toggles the application between full screen and minimized.
Application Minimize
Minimizes the application.
Application Close
Closes the application.
Mute RFID Tag Reader
Mutes the RFID Tag Reader.
The RFID Tag Reader is an optional Add On for VisTool MK2 which permits user login via an
RFID tag. This control signal can be used to mute the reader.
Disable RFID Tag Reader
As above, but the control signal disables the RFID Tag Reader.
Select 1 to 32
When the
Select 1
control signal is active, the VisTool screen is switched to page 1, where
page 1 is the page index within the VisTool Editor configuration.
When the
Select 2
control signal is active, the VisTool screen is switched to page 2.
And so on up to page 32.
The following control outputs appear under “Logic -> <GroupName> -> VispageSwitch” in the 'Tree Selection'
window:
Selected 1
True when Page 1 is selected.
Selected 2
True when Page 2 is selected.
etc.
Etc. up to 32.
Use the
Selected 1
to
32
outputs as feedback to the control signal (for example, to light the MF Key which
switched the page).