The images below show the functionality of the Central and Combo modules defined by the standard
configuration.
CR & HP - Central Module
CR & HP - Combo Module
Monitor Source Selection
For the Control Room and Headphone outputs, there are 16 monitor sources available. The current selection lights in cyan
(for CR) and green (for HP).
The first six sources can be selected directly from the surface:
PGM 1
,
PGM 2
,
PGM 3
,
Rec
,
Aux 1
and
On Air
. On a Combo
module, for the CR output, this drops to four sources:
PGM 1
,
PGM 2
,
Rec
and
On Air
. The
Soft Select
key provides access
to the other sources. This key works in conjunction with the GUI as described below.
If you wish the headphones to follow the CR monitor source selection, then press
Follow Mon
(in the HP section).
If you wish to monitor PFL on the CR output, then press
PFL
(in the CR