diamond - User Manual
Version: 8.0.0/1
Exported on: 24 October, 2023
77
/
228
2.
3.
1.
2.
3.
4.
Log in as either Supervisor or Administrator. The default passwords
are
orion
for Supervisor and
hydra
for
Administrator.
Select the "Surface Modules" tab and look at the
Act. Slot
values - these show the active slot ID for each
module.
The active
slot
ID can
be changed either, permanently, by editing
the
Dflt
(default)
value or, temporarily, by loading one of
the alternate mappings (
Map 1
to
4
).
Editing the Default Slot IDs
During the initial setup, you should use
the
Dflt
value to assign the correct slot ID to each physical module. This is done as
follows.
Type the required slot ID into the
Dflt
field - the edited value and
Set
Slot
button
highlight in yellow.
Press
Set Slot
to
make the assignment.
Wait for
the
Act. Slot
field
to update and check its value.
Repeat these steps for each module.
The screenshot below shows how the Web UI looks when a default value is changed but not yet saved.