diamond - User Manual
Version: 8.0.0/1
Exported on: 24 October, 2023
137
/
228
6.13 diamond - Metering
diamond supports a number of metering elements that can be used to configure input and output metering. The number of
meters, and their design, are determined by the configuration. Options include the meter type, source, scale and color-
coding.
Metering Locations
The diamond surface includes a signal present meter on every fader strip. All other meters are optional according to the
configuration.
The information below describes the metering defined in the standard configuration. The operation may vary if the
configuration is customized.
Metering on the Surface
1. Fader Strip Meters
diamond includes a signal present meter in the Source Display on every fader
strip.
The metering point is fixed and comes after the source's input section and before all processing.
2. Central/Combo Module Meters
A mono or stereo meter can appear in the two large displays on the Central or Combo module. These meters are defined by
the configuration and so their operation can vary.
In the standard configuration, the meters show the level of the CR and HP monitor outputs. The metering point comes after
the monitor source selector and before the volume (including mute/dim).