diamond - User Manual
Version: 8.0.0/1
Exported on: 24 October, 2023
193
/
228
•
•
•
•
7.8 diamond VX - System Health
The
Health
indicator shows the health of the system. A white tick shows that everything is ok. If there is a problem, then a
red exclamation mark appears.
1.
In each case, touch the
Health
indicator to show more information (in the 'System Health' dialog box).
In the following example, the system health is ok.
In the next example, there is a synchronization error.
The individual components are named as follows:
Fan Main Board
&
Fan Slot
- the four cooling fans inside Power Core. A health error is triggered by a reduction in the fan
speed.
PSU 1
&
PSU 2
- the dual power feeds to Power Core: PSU 1 = the AC input; PSU 2 = the DC input. A health error is
triggered by a drop in the input
voltage.
Sync
- the sync signal connected to Power Core. In the standard configuration, Power Core is set to operate as a PTP
slave, and so a health error indicates a problem with the incoming PTP signal. The sync source can be modified by
editing the configuration (using the ON-AIR Designer). For more information,
Temperature
- the status of the temperature inside Power Core. A health error is triggered when the internal
temperature exceeds 71° Celsius.
2.
Touch the
X
(top right) to close the 'System Health' dialog box.