35
CODE
DESCRIPTION
CORRECTIVE ACTION
SP in
Input
voltage low
•
Check incoming voltage to GFCI
•
Check incoming voltage to spa pack
SP OH
Water
temperature
overheat
Open the spa cover and add cold water
through the filter
SP Ot
Internal
overheat
•
Open the access panel to the spa pack
(below the control panel) and allow
two hours to cool down
•
Reset GFCI breaker
Low-Level Settings
The spa pack – located inside the spa below the
topside control panel – has a service panel used to
set your spa’s low-level programming options. During
troubleshooting, you may need to check or reset these settings.
Resetting the Spa Pack –
To reset the spa pack, press the Select
button twice.
Breaker current setting
– To adjust the breaker current setting (Br),
press the Select button and then press the Change button. The
normal current settings are:
For 240V 60Hz spas:
Br = 40
For 240V 50Hz 1
φ
spas:
Br = 1P
For 240V 50Hz 2
φ
spas:
Br = 2P
For 240V 50Hz 3
φ
spas:
Br = 3P
Low-level setting
– To reset
the low-level setting (LL),
press and hold down the
Select button for 5
seconds. Use the Change
button to set LL=(see
below) even if it is the
present value. Press Select
to save.
Limited (1304), LL=05
IR Receiver
Topside
Heater 2
Heater 1
Pump 1
Pump 2
Pump 3
Blower
Circulation
Pump
Ozonator
Stereo
Light
Interface
Change
Select