background image

  

   For HELP, call La-Z-Boy

®

 Hot Tubs at 1.800.465.2933. 

OWNER’S MANUAL 

 

La-Z-Boy

®

 Hot Tubs 

335 Superior Blvd.  

Mississauga, ON L5T 2L6 

1.800.465.2933 

www.lazboyhottubs.com 

Registration of your hot tub is the Lazboy® Hot Tubs Retailer’s responsibility. Please verify 

with your Lazboy® Hot Tubs Retailer that your hot tub has been registered for your warranty.

 

Contents subject to change without notice 

2020 

La-Z-Boy 

is a trademark of La-Z-Boy Incorporated and is used under license to 2217044 Ontario Inc.

 

Summary of Contents for Premier Series

Page 1: ...azboyhottubs com Registration of your hot tub is the Lazboy Hot Tubs Retailer s responsibility Please verify with your Lazboy Hot Tubs Retailer that your hot tub has been registered for your warranty...

Page 2: ...cts may be configured differently to meet local electrical requirements Dimensions are approximate La Z Boy Premier Hot Tubs Owner s Manual Table of Contents Safety Information 03 Guarantee 08 Introdu...

Page 3: ...E RADIO OR TELEVI SION WITHIN 1 5M 5FT OF THIS SPA OR HOT TUB 13 CHILDREN SHOULD NOT ENTER A HOT TUB WHERE THE WATER TEMPERATURE EXCEEDS BODY TEMPERATURE 37 C 98 6 F 14 DO NOT ALLOW CHILDREN TO SUBMER...

Page 4: ...N AL TERNATIVE A SPA MAY BE INSTALLED WITHIN 1 5M 5FT OF METAL SURFACES IF EACH METAL SURFACE IS PERMANENTLY CONNECTED BY A MINIMUM 8 AWG 8 4 mm2 SOLID COPPER CONDUC TOR TO THE WIRE CONNECTOR ON THE T...

Page 5: ...ns provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment 7 At least two lugs marked BONDING LUGS are provided...

Page 6: ...site immediately upon completion of spa installation Important It is extremely important that this sign be permanently placed in clear view of persons using the spa hot tub Occasional spa hot tub user...

Page 7: ...___________________________________ Address __________________________________________________________________ Telephone __________________________________________________________________ Date Deliver...

Page 8: ...8 For HELP call La Z Boy Hot Tubs at 1 800 465 2933...

Page 9: ...9 For HELP call La Z Boy Hot Tubs at 1 800 465 2933...

Page 10: ...damages caused by improper installation or use of spa hot tub improper or otherwise Notes _______________________________________________________________ ______________________________________________...

Page 11: ...lities of the floor on which the spa will reside Most homes meet the requirement of 250 pounds per square foot 6 Ensure that your spa hot tub will fit into the space you have chosen and the delivery r...

Page 12: ...ed with a breaker or according to IEEE wire regulations for export models Failure to do so will cause equipment damage and will not be cov ered under your guarantee All spa hot tubs must be protected...

Page 13: ...tub Means for disconnection must be used with fixed wiring configurations in accordance with local wiring rules IMPORTANT To allow the GFCI to function properly connect the white Neutral wire from the...

Page 14: ...med by a qualified electrician in accordance with the National Electrical Code or the Canadian Electrical Code and all federal state and local codes and regulations in effect at the time of installati...

Page 15: ...ur local dealer for assistance For best results read each step in its entirety before pro Running the spa hot tub pump dry without water running through it can cause IMMEDIATE damage and will void the...

Page 16: ...e tight 7 Clean out any foreign debris from within the service access area or inside of the spa hot tub itself 8 With the drain open and filters removed thoroughly rinse out the spa hot tub with warm...

Page 17: ...the other end of the hose point the pre filter into a suitable drain turn on the water and allow any sediment to be flushed down the drain Once the water stream runs clear turn off the hose 4 Put the...

Page 18: ...tically trip the spa hot tub circuit breaker Only if pushing this button successfully trips this circuit breaker should you reset this breaker and proceed to the next step If this breaker does not tri...

Page 19: ...ng a pump off on will prime it Only do this four times CAUTION NOTE In order to prevent damage to your pillows caused by the gassing effect of the chemicals we do recommend to remove them when the spa...

Page 20: ...h a good quality test kit Maintain a total alkalinity level of 80 to 120 ppm Total alkalinity is the measure of alkaline buffers in your water These buffers protect the water against sudden changes in...

Page 21: ...artially drain your spa hot tub Use a good quality pre filter to the supply line when refilling it SANITIZATION CHLORINE BROMINE Once your hardness level is proper it is imperative that you do not use...

Page 22: ...The following table summarizes the desired water quality properties your spa hot tub should have Test Desired Value Total Alkalinity 80 to 120 ppm mg L pH 7 2 to 7 8 Hardness 200 to 400 ppm mg L Bromi...

Page 23: ...ol panel uses a paged style menu system to operate and program your spa Basic button functions are described next Figure 11 Topside Control Panel JET 1 KEY WHICH CONTROLS PUMP 1 LIGHT KEY WHICH CONTRO...

Page 24: ...ack to the main Settings menu TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT After you exit the programming mode your hot tub will automatically heat to the factory preset default temperature of 38...

Page 25: ...economy mode and will run a normal 24 hours of filtration a day Energy Savings The spa will be in economy mode during the peak hours of the day and resume normal mode on the weekend Super Energy Savi...

Page 26: ...time and duration are set in 30 minute increments Once you have set the schedule use Jet 1 key to go back Ensure that you have selected the de sired Water Care option in the main Water Care menu FILTE...

Page 27: ...hen prompted Once you have con firmed the task will be reset STANDBY The Standby mode allows you to service your spa Pumps will stop for 30 minutes and automatically restart after this time Once Stand...

Page 28: ...ot make changes in this section unless you are a qualified electrician FACTORY RESET In this section you can see erros that have been archived by the system Use the UP and DOWN keys to move through th...

Page 29: ...a filter cycle heating requests and smart winter mode purging for 30 minutes to perform quick spa maintenance DRAIN MODE If you wish to put your spa into DRAIN MODE press the FUNCTION key beside the...

Page 30: ...lve located near the seat to allow the water to flow out of the jets and provide you a sequence of massage techniques that will soothe your aching back muscles Figure 12 Comfort Zone Massage Control C...

Page 31: ...PAUSE AUDIO POWER ON OFF NEXT TRACK VOLUME UP DOWN AUXILLARY AUDIO DEVICE BLUETOOTH AUDIO DEVICE LAST TRACK NOTE If you are using a device with Bluetooth technology it must be connected for functions...

Page 32: ...main cause of respiratory eye and skin irritation typical ly associated with chlorine Harmful corrosive off gassing is also dramatically reduced through this process MAINTENANCE AND SERVICE While oper...

Page 33: ...Home Internet router Both RF transmitters are pre linked to one another enabling an imme diate and perfect communication between user and the spa 1 Installing the home transmitter The home transmitte...

Page 34: ...e spa facing the house The in touch 2 spa transmitter must be installed under the spa skirt at least 12 30 cm away from any metal component or structure as close as possible to the house to optimize t...

Page 35: ...spa s breaker to turn the spa transmitter off Wait a little and put the breaker back on Within a few seconds pairing will be completed and both transmitter status lights will turn to blue 4 Transmitte...

Page 36: ...times longer than regular signal No need for repeaters or boosters your spa will always remain within reach in typical backyard settings 6 Application Download application The in touch app allows you...

Page 37: ...e selected it wait until your de vice confirms the connection On the Internet The in touch 2 allows you to use the Internet to control your spa from anywhere in the world In order for them to communic...

Page 38: ...p your Wi Fi on your device Before using your application go to the Wi Fi section of your device s settings Make sure you are connected to your home network This needs to be the same Wi Fi pro vided b...

Page 39: ...en tap on it to open it The first time you use the application a message will ask you in touch 2 Would like to send you notifications If you choose Allow the application will send you notifications ab...

Page 40: ...bs at 1 800 465 2933 Login page Before using your application you must create an account first and then you ll be able to sign in Your account will give you the opportunity to have access to your spa...

Page 41: ...ubs at 1 800 465 2933 New account creation When you choose to create a new account you agree at the same time the Terms of Service and the Privacy Policy You can read them at any time through this lin...

Page 42: ...tion To detect your spa you need to connect your mobile device to the same network to which you connected your Home Transmitter Once you have done a connection with the spa its name will be saved on t...

Page 43: ...call La Z Boy Hot Tubs at 1 800 465 2933 Home page The main screen gives you access to your accessories water temperature water care and settings The app is mirroring the top side control keypad over...

Page 44: ...our spa hot tub Figure 14 Feature Callouts 1 Lock down tab 2 Double stitched seams 3 Marine grade cover material 4 Edge overlap material 5 Grip handle 6 Aluminum channel 7 Heat sealed insulation 8 Che...

Page 45: ...demineralizer found at any local pool spa store Using a pre filter can remove these contaminants before they get into your spa CLOUDY white water Although a normal condition immediately after filling...

Page 46: ...be easily resolved over the phone a local technician can be dispatched to your home The service technician may assess reasonable travel charges during on site repairs What happens when my guarantee ex...

Page 47: ...r layer of insulation is added to the base Third an inner layer of insulation is wrapped around the entire cabinet Fourth a reflective foil is layered on the inner layer of insulation Fifth an air tig...

Page 48: ...on all pumps to make sure that there are no leaks Put the access panels back on Turn on the GFCI breaker Figure 15 Bleeding Air How should I clean my spa Use non sudsing cleaners and non oily polishe...

Page 49: ...ine Circulation pump not running in constant filtration mode Temperature limit reached This is normal When the water temperature is 2 F over the set point and warmer than 95 F the pump automatically t...

Page 50: ...it breaker panel No flow Closed jets ACV open Open jets Close ACV Nothing works Breaker has tripped Check and reset breaker If problem persists check for loose electrical connections Check for Neutral...

Page 51: ...pside control panel High ambient temperature Remove the cover from the spa Water will not heat Thermostat is set too low Check and reset to desired temperature Air open Close air control valve Dirty f...

Page 52: ...ck if the problem persists HL The water temperature at the heat er has reached 119F Do not enter the spa water Measure the water temperature and compare the reading Check for flow ob structions Call f...

Page 53: ...e the panel up in the opening and lift it in place and the mag netic latches will engage with the panel so you can shift it place and complete the rein stallation COLOR COORDINATED COVER 1 The heat sh...

Page 54: ...spa hot tub again Call your local dealer to order replacement filters and filter cleaner Figure 16 Drain Operation 1 Turn Power Off turn the power off at the spa consoles and deactivate disconnect sw...

Page 55: ...clean in this same manner COMFORT REST PILLOWS Remove and clean the Comfort Rest Pillows as needed using an all purpose cleaner and rinse thoroughly with warm water SURFACE The acrylic surface of you...

Page 56: ...y baster where necessary to add potable biodegradable RV antifreeze to areas such as pump wet end jet channels filter housing blower chan nels DO NOT USE AUTOMOTIVE ANTIFREEZE Important mixing potable...

Page 57: ...cteria mold and viruses while prolonging equipment life pH The scientific scale for measuring Hydrogen Ion concentration 0 to 14 that shows the acid alkaline content in water Pump The electrical compo...

Page 58: ...________________________ _____________________________________________________________________ _____________________________________________________________________ ___________________________________...

Page 59: ...59 For HELP call La Z Boy Hot Tubs at 1 800 465 2933 IN YE 5 EU WIRING DIAGRAM...

Page 60: ...60 For HELP call La Z Boy Hot Tubs at 1 800 465 2933 IN YE 5 NA WIRING DIAGRAM...

Reviews: