Defender Press Brake Guarding System Operation Manual
LS-CS-M-069
Page 34
Original Language Version: 1.04
Released:
01/04/2020
6.9.1
Exiting Back Gauge Mode
To turn off Back Gauge mode, press the
BACK GAUGE
button when the tools are open. If the
tools are not open, the Status window will display the message
Open tools to enable button
function
. The Mode Select screen will again appear as shown in
6.10
Tool Set-up Mode (optional)
Tool Setup mode is selected from the Main screen. When selecting Tool Setup mode the
tools must be open with the laser above the mute point and clear of any obstructions. If these
conditions are not met, the Status window will display the message
Open tools to enable button
function
.
Warning: NO OPTICAL PROTECTION IN TOOL SET-UP MODE
In Tool Setup Mode, all optical guarding is deactivated. Although the Defender
Press Brake Guarding System ensures that the machine does not exceed safe
speed in this mode, particular caution must still be exercised.
Tool Setup mode is password protected and only accessible to operators with Supervisor
level access. When the
TOOL SETUP
button is pressed the screen prompts the operator to
enter the Supervisor access code, as shown in
If the code is correct the Defender screen proceeds to the Tool Setup mode screen, and the
Defender system will now behave as detailed in
Section 3.9
. If an external mute lamp has
been installed it will be switched
ON
to indicate that optical protection has been de-activated.
a
e
ENTER
0000
Enter access code
Figure 6-17: Tool Setup Mode Access Screen