5. For Units With Timer 

Timer Functions 

A.  Set Clock 
B.  Set Timer STD/AUTO 
C.  Set ON/OFF Time* 
D.  Set Sleep Delay Time* 
E.  Filter Life 
F.  Service 
G.  Keypad Lock  

 

* ON/OFF Time & Sleep Delay Time only 
operate in AUTO Mode. 

To select a Timer Mode 

Press  the  (

Prog

)  button  until  the  desired 

mode  is  displayed  on  the  screen.  Press 
the  (

Accept)

  button  to  confirm  selection.

 

Pressing  (

Cancel

)  button  at  any  time 

returns  the  unit  to  the  main  menu.  Any 
functions  previously  accepted  will  be 
retained.

 

Note:

  The  display  will  revert  back  to  main 

menu from any mode if a button has not been 
pressed for 1 minute.

 

A) Setting the Clock 

 

Select the clock mode  
(Prog>

Clock

>Accept) 

Display Shows

:  “Set Clock Day”. 

 Press  the  (

UP

)  button  until  the  desired 

day appears on the screen and press the 
(

Accept

) button to confirm selection. 

 

Display Shows

: “Set Clock HOUR” 

Press  the  (

UP

)  button  until  the  desired 

hour (24 Hour Time) appears flashing on 
the screen and press the (

Accept

) button 

to confirm selection. 

 

Display Shows

: “Set Clock MIN” 

Press  the  (

UP

)  button  until  the  desired 

minute appears flashing on the screen. 
Press  the  (

Accept

)  button  to  confirm 

selection  and  the  display  reverts  to  the 
main menu. 

 

B) Set Timer to STD/AUTO Mode 

 

Select the Timer STD/AUTO mode 
(Prog>

Timer STD/AUTO

>Accept)

 

 

Display Shows

:  “STD” 

Pressing  the  (

UP

)  button  alternates  the 

“STD”/“AUTO”  icons.  STD  operation 
means the unit operates 

24 hours

 a day. 

Auto  mode  reverts  the  unit  to  operate  at  the 
preset  times  on  the  timer.  Press  the  (

Accept

button  to  confirm  selection  and  the  display 
reverts to the main menu. If the timer is in AUTO 
mode,  pushing  any  timer  key  will  reactivate  the 
unit. The unit will operate normally until the next 
programmed “Off” time. 

 

 

C) To Set ON/OFF Times 

 

Select the Timer ON/OFF mode  
(Prog>

Set ON/OFF times

>Accept) 

Note:  to  set  the  unit  to  be  in  off  mode  for  an 
entire day, set the “on” and “off” times to be the 
same eg: On = 0:00 Off = 0:00 

 
 

Display Shows

:  “SUN” “7:00 – 7:00”              

“Set ON hour”.  

Press  the  (

UP

)  button  until  the  desired  hour 

appears  on  the  screen  and  press  the  (

Accept

button to confirm selection. 

 

Display Shows

:  “SUN” “7:00 – 7:00”               

“Set ON minute”.  

Press  the  (

UP

)  button  until  the  desired  minute 

appears  on  the  screen  and  press  the  (

Accept

button to confirm selection. 

 

Display Shows

:  “SUN” “7:00 – 7:00”            

“Set OFF hour”.  

 

Press  the  (

UP

)  button  until  the  desired  hour 

appears  on  the  screen  and  press  the  (

Accept

button to confirm selection. 

 

Display Shows

:  “SUN” “7:00 – 7:00”              

“Set OFF Minute”.  

Press  the  (

UP

)  button  until  the  desired  minute 

appears  on  the  screen  and  press  the  (

Accept

button  to  confirm  selection  and  advance  to  the 
next day.   

Display Shows

: “MON” “7:30 – 15:30”           

“Set ON hour”. 

Note:

  Continue  with  same  procedure  for  Monday 

through to Saturday. 

 

D) To Set Sleep Delay Time. 

 

Select  the  Sleep  on/off  mode  (Prog>

Sleep 

DelayTime

>Accept)

 

Display Shows

:  “Sleep DelayTime”                             

“ OFF”.  

The  sleep  function  puts  the  unit  in  a  standby 
mode  after  a  user  defined  period.  The  Sleep 
Delay  will  be  factory  set  to  OFF  as  the  default 
setting.  Pressing  the  (

UP

)  button  increases  the 

delay time up to 6 hours.   

8. 

 

H. TAP OUTLET 

 

To  prevent  damage  during  transport  the 
tap  is  wrapped  and  placed  within  the 
boiling water unit. 
The  tap  is  connected  to  the  tap  extension 
by a chrome-plated nut and tightened using 
a 29 mm AF spanner. 

J. ELECTRICAL REQUIREMENTS: 

WARNING:

 

This boiling water unit contains electronic 
equipment and insulation tests must only 
be conducted between neutral and earth 
or between active and earth. A minimum 
insulation test result of 660 k

 

(approximately) is normal for this unit and 
complies with AS/NZS 3760:2003 clause 
2.3.3.2.1  for 3 to 15 litre products and 
AS/NZS 3000:2007 clause 8.3.6.2(ii) for 
25 and 40 litre products. 

 

• 220 –240 Volts AC, 50 Hz, Single Phase 
• 10 Amps on 3, 5, 7.5,10 & 15 litre models 
• 15 Amps on 25 litre model 
• 20 Amps on 40 litre model 

A flexible cord is supplied on all 3, 5, 7.5, 
10 and 15 Litre models. Do not loosen the 
cord  grip  or  pull  excess  cord  into  the 
Lazer.  If  the  supply  cord  of  this  unit  is 
damaged,  it  must  be  replaced  by  the 
manufacturer  or  a  qualified  service 
person. 

The 25 and 40 litre models must be installed 
with  fixed  wiring.  A  means  of  disconnection 
from  all  active  (phase)  conductors  of  the 
power  supply  must  be  incorporated  during 
installation  in  accordance  with  the  wiring 
rules. 

 

4. OPERATION 

 

When the installation is complete, first turn on the 
water supply before switching on the power.  

 

IMPORTANT

:    

On  initial  start-up  the  timer  screen  will  display 
“CALIBRATING DO NOT INTERRUPT”. The unit 
automatically runs through a set-up cycle to detect 
the  boiling  point  of  water.  This  will  take  between 
18 to 30 minutes (depending on the unit capacity) 
and steam will discharge from the vent pipe for a 
short time.  Do not operate the tap during the set-
up cycle because it may affect the unit operating 
temperature.   

 

The  unit  is  programmed  to  automatically  operate 
24  hours  a  day,  7  days  a  week.  It  is  highly 
recommended  for  the  user  to  program  the  timer   
(if the unit supplied has one), as this will increase 
the  life  of  the  unit,  and  consume  less  power  (see 
Section 5 for how to program the timer).  
The  electronic  controller  constantly  monitors  and 
controls  the  water  level  and  water  temperature  to 
optimise the boiling water delivery. 
 
 

 

 

 
 

 
 
 
 
 
 
 

SPECIFICATION CLASSIC SERIES 

  

3 Litre 

5 Litre  7.5 Litre  10 Litre  15 Litre  25 Litre 

40 Litre 

 Approx Weight (kg) Empty 

10 

15 

17 

19 

 Approx Weight (kg) Full 

10 

15 

19 

22 

34 

47 

67 

 Minimum Water Pressure kPa 

50 

50 

50 

50 

75 

75 

100 

 Maximum Water Pressure kPa 

1000 

1000 

1000 

1000 

1000 

1000 

1000 

 Element Size kW 

1.8 

2.4 

2.4 

2.4 

2.4 

3.6 

4.6 

 
 
 
 
 

Operation based on an inlet 

water temperature of 18ºC

 

Lazer Size

 

Approx 

Recovery 

Litres / Hour

 

Approx. time to 

heat full Capacity 

(in minutes)

 

3.0 L 

17.5 

12 

5.0 L 

21 

15 

7.5 L 

21 

22 

10 L 

21 

29 

15 L 

21 

40 

25 L 

33 

40 

40 L 

41 

50 