Operating instructions
– LBA4/6/7 – 2017 Version
16
4.2
Main features
This barrier comprises several sub-assemblies that are very easy to replace: sheet metal, motor unit,
boom support for aluminium boom and electrical board.
Barrier
LBA4
LBA6
LBA6R
LBA63PK
LBA7
LBA7R
LBA74
Sheet metal
Housing and hatch made of 2 mm thick sheet metal with cataphoresis treatment and RAL 5015 paint
Aluminium top cover and RAL 9010 paint
(other colours possible as an option)
Boom
Oval
Aluminium 84
x 57 mm
Oval
Aluminium 84 x 57 mm
Oval
Aluminium
84 x 57 mm
Straight or
folding
Oval aluminium 84 x 57
mm
Or Rectangular Fibre 145 x
65 mm
Oval
Aluminium
135 x 93
mm
Max. length
4 m
6 m
3.80 m
7 m
6 m
4 m
Motor
Three-phase 0.18 kW - 230 Vac
Reversibility
No
Yes
No
Yes
Counterbalance
Compression spring
Speed
Adjustable speed and rates controlled by a 0.25 kW variable frequency drive
Operating time
3 to 6 s
2 to 9 s*
0.8 to 3 s
2 to 9 s*
2 to 4 s
Control
Electronic
board
PLC
Position
sensors
Inductive (contactless)
*: Take into account the boom length and its accessories
4.3
Power supply
Designation
Unit
Min.
Typ.
Max.
Power supply
Vac
210
230
250
Frequency
Hz
48
50
52
Consumption
W
-
180
250
4.4
Conditions of use
Immunity
Standard code or level
Operating temperature
From -30°C to +55°C
Power line disturbances
Immunised against power line disturbances less than 100 ms
Humidity
Maximum degree of humidity: 95% up to 30°C; 50% above 30°C
Water spraying
Code AD5: water jet washing sprayed in all directions, or high-pressure washing
at a minimum distance of 1 m
Solid matter
Code AE4: protection against particles larger than 1 mm
Wind
Wind resistant up to 140 km/h
Corrosive substances
Code AF2 more specific conditions of the type salt mist, exhaust fumes form
vehicles.
Impacts
Code AG3
Vibrations
Code AH2
Flora and mildew
Code AK2
Fauna
Code AL2
Electromagnetic, electrostatic or ionising
effects
Code AM6
Solar radiation
Code AN2
Lightning
Code AQ2