Operating instructions
– LBA4/6/7 – 2017 Version
30
2
nd
step: Adjusting the stops (except for LBA4)
For irreversible barriers, stops are used for safety purposes in the event of faulty sensors.
To adjust the stops:
1-
Remove the top cover
2-
Switch off the barrier
3-
Unlock the locknut of the stop that you want to adjust
4-
Screw or unscrew the stop until it locks the boom to avoid over-travel (slightly after the final
position)
5-
Lock the stop’s locknut
LBA 6:
LBA 7:
Opening stop
Closing stop
Opening stop
Closing stop