Operating instructions
– LBA4/6/7 – 2017 Version
42
Once the user is selected and, where applicable, the password has been entered, you will access the
PLC's main menu, the "PLC MENU" screen is displayed:
13.2 "INFORMATION" - Characteristics of the programme:
The "INFORMATION" function provides you with fast access to the various advanced pieces of
information on the contents of the board.
Simply scroll through the information using the directional arrows.
The available information is (in the order of reading):
-
MAC address of the "µC1" microcontroller (main microcontroller)
-
Version of the firmware present in the "µC1" microcontroller
-
Latest date of the firmware update of the "µC1" microcontroller
-
Version of the firmware present in the "µC1" microcontroller (microcontroller for motor
control)
-
Latest date of the firmware update of the "µC2" microcontroller
-
Project name
-
Project version
-
Product name
-
Product version
-
Date and time of the latest compilation of the project
-
Name of our company
-
Project language
13.3 "START/STOP PLC" - Starting/stopping the program:
The "STOP PLC" function allows you to stop the PLC, for example when we want to stop the barrier
without however powering down the barrier.
When the barrier is stopped, the function then becomes "START PLC" and makes it possible to start
the program again. It is also possible to reset the barrier in order to start the program again in good
conditions.
==== PLC MENU =====
INFORMATIONS [*]
STOP PLC [ ]
USER PARAMETERS [ ]
===INFORMATIONS===
------FIRMWARE uC1------
MAC XX:XX:XX:XX:XX:XX
VX.X