Operating instructions
– LBA4/6/7 – 2017 Version
70
18.6.2
LBA 6/6R/63PK
To reverse the direction of the LBA 6/6R/63PK, follow the procedure below:
A-
Remove the boom and the top cover
B-
Remove the nut at the end of the shaft using a 36 mm spanner
C- Dismantle the support of the stops by removing the 2 screws completely and the
reinforcement.
D- Tilt the plate to loosen the counterbalance
E-
Dismantle the quick link from the counterbalance chain using needle-nose pliers
F-
Remove the counterbalance unit with its chain
G- Pivot the plate 180°
H- Reinstall the counterbalance unit by engaging the chain in the other hole of the upper steel
sheet
I-
Tilt the plate on the chain side and reinstall the quick link
J-
Pivot the detection cam
K-
Reinstall the support of the stops in the other direction by retightening the 2 screws
L-
Reinstall the nut at the end of the shaft and lock it
M- Physically reverse sensors no. 1-2 and 4
N- Reverse the two phases for the variable frequency drive
O-
Readjust the stops and sensors (see paragraph “9.3 Adjustment of stops and sensors”)
F
180°
G
H
B
C
D
E