Operating Instructions
– LBA63 TOLL HIGHWAYS – 2019 Version
69
F-
Thread the cable through the notch in the cover
G- Insert the nut and block it with a 15 spanner
H- Insert the lock nut to prevent the assembly from becoming loose and block it with a 15
spanner
Check that the connector/cover assembly is held correctly
I-
Install the cover fitted with the tubing and the sensor; the cable must be flexible and not taut
(inside the cover)
J-
Install the second part of the protective cover
K-
Remove the washer and the nut fixed on the second connector and check for the heat-shrink
tubing at the connector outlet
L-
Insert the connector in the housing
M- Inside the housing, position the washer and nut and using a 15 spanner block the connector
on the housing (insert thread lock to stop the nut from coming loose)
Check that the connector/housing assembly is held correctly
N- Thread the cable into the tubing without attaching it to the base. The wire must be flexible
and not taut.
O- Connect the sensor to the terminal board
F
G
H
K
L
M
N