Operating Instructions – LBAT10/20/PMR – Version 2017
24
8
Electrical connection:
The turnstile is connected electrically to the terminal board on the bottom of the control panel. There is
one panel for each revolving door. Each revolving door is separate. The terminals are as follows:
•
Direction 1 and direction 2 access commands (terminals 1 to 3):
These are normal access commands. The commands must be NO pulsed dry contacts.
o
Direction 1:
clockwise rotation (“passage to the left”)
o
Direction 2:
anticlockwise rotation (“passage to the right”)
•
Forced locking/unlocking commands (terminals 4 to 9):
Forced commands are direct accesses to the electromagnets and are used to force the locking or
unlocking of the turnstile in one direction or the other. Forced commands must be maintained NO dry
contacts.
These commands are forced and maintained commands. They must not be used in
place of normal access commands (terminals 1 to 3).