Operating Instructions – LBAT10/20/PMR – Version 2017
34
11 Cleaning and maintenance:
The power supply must be cut off before carrying out cleaning and maintenance
operations on the turnstile.
11.1 Cleaning:
Cleaning frequency depends mainly on the environmental and climate conditions dictating turnstile use.
Do not use abrasive products for cleaning as they risk damaging electric cables or
the turnstile coatings.
Protect the conductive components from damp and dust to prevent short-circuits.
Cleaning to take place:
•
Outside cleaning, checking for lack of impacts, scratches, etc. that could encourage corrosion
•
Inside dust removal from the mechanical and electrical sections
11.2 Maintenance schedule:
Frequency
Operation
Every six months
•
Cleaning operations described previously
•
Checking that all the hardware including the ground
fixing and the accessories are tightened
•
Checking the connectors on the control panel or PLC
•
Tightening wires, good contact in the terminals
•
Visual inspection of the position of the revolving door
Annual
•
Checking the various turnstile settings
•
Checking that the display LEDs are working properly
•
Checking that the LED lights are working properly
•
Checking that the disconnector is working properly
•
Checking that the opening remote controls are working
properly in both directions