ET60 Installation and Operating Instructions
7
Operating Instructions
To Operate Meter
Insert coin/token. The display will briefly show ‘Coin’. The display will then show the
remaining credit. If the credit is greater than one hour it will be displayed in hours &
minutes, e.g.; 2 hours will be displayed as ‘02:00'. If the credit is less than one hour it
will be displayed in minutes & seconds, e.g.; 40 minutes will be displayed as ‘40:00'
and an indicator will flash on the display to show this (Figure 4).
If the meter is fitted with the optional key override switch then inserting the key and
turning clockwise will switch on the load, disable timing and display “FrEE”. This
action will also clear any remaining credit. To return to normal operation insert key
and turn counter clockwise.
Error Messages
Thirteen error messages are displayed to help fault finding in the unlikely event of
meter malfunction. Error messages are displayed in the format Er.xx
Er.01
Opto 1 detected an object not conforming to the required parameters.
Opto 1 is the coin sensor used to validate £1 coins, L2 & L4 tokens. If the
sensor detects that the coin is the wrong size it will show the error message.
Er.02
Opto 2 detected an object not conforming to the required parameters.
Opto 2 is the coin sensor used to validate 20p, 10p, €1, 50c coins or L1
tokens. If the sensor detects that the coin is the wrong size it will show the
error message.
Er.03
Not used
Er.04
Not used
Er.07
Opto 1 validated but St.01 is zero.
Set a value in St.01
Er.08
Opto 2 validated but St.02 is zero.
Set a value in St.02
Er.09
Not used
Er.10
Not used
Er.11
Not used
Er.12
Not used
If the following error messages are encountered contact the LCI support desk.
Er.05
Opto 1 validated but meter is configured as a 10p or 20p only.
Er.06
Opto 2 validated but meter is configured as a £1 only.
SynC
Software re-synchronising with the mains frequency