background image

7

Brightness / power supply LCN-NUI

The application of a power supply LCN-NUI is required 

® 

when  the  blue  background  light  and/or  the  Corona
surrounding lights   are being used. Apart from that, the 
red  status  LED´s  will  light  up  brighter, that  is  important 
with direct sunlight or when a  reading precision is desired 
from a long distance. 

The power supply LCN-NUI is connected to the I-Port of 
any module with year of manufacture 2013 or later, and 
supplies the T-Port over the module. 

The  brightness  of  the  status-LED´s,  as  well  as  the 

® 

Corona surrounding-light, can be reduced for the night 
operation  with  the  command 

LED  control/LED 

brightness.

 

Captions for the keys using ordinary paper and operation 
without    an  LCN-NUI,  make  the  LED´s  harder  to 
recognise by direct exposure to light.   In this case use 
plastic sheets or an LCN-NUI.

LCN-GTS6

®

   Installation guide 

LCN-GT6

®

optional

A1

L1

A2

L2

A3

L3

A4

L4

A5

L5

A6

L6

LED`s for 

®

Corona -Light

LED for O-Light

Summary of Contents for LCN-GTS6

Page 1: ...NUI required and can be switched as a decent orentation light so that the LCN GT6 LCN GTS6 can also be operated in darkness The 6 capacitive working sensor keys are situated behind a 5mm thick glass front A soft touch to the surface is enough to trigger off the functions The captions on the sensor keys can be carried out individual ly per inlay and can be changed anytime without difficulty 6 keys ...

Page 2: ...ouble touching is especially suitable for functions that should not be accidentally triggered central off switching the alarm system etc The integrated temperaturesensor supplies the measured values with a triggering from 0 1 C and thanks to its adaptive average calculation practically noiseless The 6 Status LED s in the sensor areas are individually controlled over the T Port and configuredover t...

Page 3: ...nal LCN GRT The LCN GT6 must not wobble on the wall as this would lead to false triggering That is why when installing the edges of the cavity wall mounted box should be counter sunk or the flush mounted box should not be surmounted on the wall to guarantee a flawless function of the LCN GT6 LCN GTS6 Corona surrounding light O Light Orientation light and the blue key Note Important When the temper...

Page 4: ...ssigned in the LCN PRO menu Ports The assignments can be comfortably chosen as graphics For example each line of 3 keys can be changed into 2 larger keys see the lower example Important functions can be easily operated without losing the flexibility of many keys T Ports Change mapping LCN GT6 LCN GTS6 will be automatically recognized from the module and the temperature registered in the variable 3...

Page 5: ... the connected UP x module onto the wall At the bottom area the LCN GT6 must be hooked into the corners of the mounting frame and pressed towards the wall Through pushing in the plastic slider on the side the LCN GT6 is locked firmly onto the mounting frame LCN GT6 LCN GTS6 Installation LCN GTS6 Installation guide LCN GT6 IG1 LCN ISSENDORFF Oben adjusting the mounting frame green help for insertio...

Page 6: ... ideal luminance of the status LED s Inserting the inlay into the key sensor Pull the plastic slide to the side outwards at the rear of the key sensor Insert the inscripted inlay at the bottom side of the LCN GT6 LCN GTS6 into the groove until it resists Tip If you cut off the corners of the inlay around 2 mm it will make it easier for inserting the inlay into the groove When changing the paper re...

Page 7: ... to the I Port of any module with year of manufacture 2013 or later and supplies theT Port over the module The brightness of the status LED s as well as the Corona surrounding light can be reduced for the night operation with the command LED control LED brightness Captions for the keys using ordinary paper and operation without an LCN NUI make the LED s harder to recognise by direct exposure to li...

Page 8: ...ey background LED s blue funktions OFF ON white corona LED s controllable over command GT brightness adjustable in steps temperature sensor measurement range Installation dimensions W x H x D 90mm x 90mm x 12 5mm 5mm glass thickness LCN GT6 75mm x 75mm x 10 5mm 3mm glass thickness LCN GTS6 operating temperature 10 C to 50 C air humidity max 80 rel non condensing environmental conditions use as sta...