PRIORITY LEVELS
Priority levels
Trigger signal source
Muted signal sources Active
signal sources
Indicator on the front
1
Emergency VOX switching circuit and
contact closure
MIC/LINE 1
EMERGENCY SIGNAL
EMERG
MIC/LINE 2
MUSIC
2
MIC/LINE 1 VOX
MIC/LINE 2
EMERGENCY SIGNAL
PRIO
MUSIC
MIC/LINE 1
3
MIC/LINE 1, contact closure during chime
tone output
MIC/LINE 1
EMERGENCY SIGNAL
PRIO
MIC/LINE 2
MUSIC
4
MIC/LINE 1, contact closure after chime
tone output
MUSIC
EMERGENCY SIGNAL
PRIO
MIC/LINE 1
MIC/LINE 2
5
–
–
EMERGENCY SIGNAL
–
MIC/LINE 1
MIC/LINE 2
MUSIC
CONNECTION EXAMPLES
Microphone Signal
Microphone Signal
Mute Contact
Mute Contact
1
2
The connection for a mute switch/button in MIC/LINE channel 1 can be used for two devices at the same time (muting of a music signal or activation
of the gong/signal tone). In this case, the mute contacts of both devices must be connected to poles C and + of the terminal strip connections for