background image

4

DEUTSCH

ENGLISH

CAUTION

Never remove the cover – there is a risk of electrical shock. The device does not contain any parts 

inside requiring repair or servicing by the operator. Only allow qualified service technicians to carry out 

maintenance and repairs.

To prevent electrical shock, do not touch exposed speaker cables/wires while the amplifier is in operation!

CLASS 2 

WIRING

High output voltage; risk of electrical shock! A trained person must install the wiring for the loudspeaker connection terminals using 

prefabricated wiring systems!

Warning! This symbol indicates hot surfaces. Specific housing parts can become hot during operation. Allow the device to cool for at 

least ten minutes after use. Only then can it be transported or touched.

Warning! This device is designed for use up to a maximum height of 6,562 feet above sea level.

Warning! This device is not intended for use in tropical climates.

Protective earth (ground)

To identify any terminal which is intended for connection to an external conductor for protection against electric shock in case of a 

fault, or the terminal of a protective earth (ground) electrode.

  

"ON" (power)

To indicate connection to the mains, at least for mains switches or their positions, and all those cases where safety is involved.

  

"OFF" (power)

To indicate disconnection from the mains, at least for mains switches or their positions, and all those cases where safety is involved.

WARNING: HIGH-VOLUME AUDIO PRODUCTS!

This device is intended for professional use. The commercial operation of this device is subject to applicable national regulations and directives for 

accident prevention. As the manufacturer, Adam Hall is legally bound to specifically point out potential health risks. Hearing damage caused by high 

volumes and prolonged exposure: Using this product can generate high sound pressure levels (SPL), which can cause irreparable hearing damage to 

artists, employees, and audiences. Avoid prolonged exposure to high volumes above 90 dB.

INTRODUCTION

IPA 424 T and IPA 412 T are DSP-based 4-channel installation amplifiers in 19” rack format specially developed for professional audio installations. 

They have integrated transformers per channel and offer connections for 100 V/70 V and Low-Z systems up to 4 Ohm. For optimal energy efficiency, 

the devices have auto standby switches. A slot for optional expansion cards enables the IPA amplifier, including all internal DSP parameters to 

be controlled via Ethernet and, thanks to the Dante AoIP connectivity, to be integrated into larger installation networks. The IPA series can also 

interact with remote units and paging microphones from LD Systems via a REMOTE audio and control bus based on a CAN (Controller Area Network) 

architecture. This combination of powerful functions makes the IPA series the best choice for permanent installation.

Summary of Contents for IPA 412 T

Page 1: ...USER S MANUAL BEDIENUNGSANLEITUNG More languages online at ld systems com IPA 412 T 424 T INSTALLATION DSP POWER AMPLIFIER LDIPA412T LDIPA424T ...

Page 2: ...NTS 5 ASSIGNMENT OF THE TERMINAL BLOCK CONNECTIONS AND SETUP EXAMPLES 11 TECHNICAL DATA 11 MANUFACTURER S DECLARATIONS 14 DEUTSCH SICHERHEITSHINWEISE 15 EINFÜHRUNG 16 EIGENSCHAFTEN 16 LIEFERUMFANG 17 ANSCHLÜSSE BEDIEN UND ANZEIGEELEMENTE 17 BELEGUNG DER KLEMMBLOCKANSCHLÜSSE UND SETUP BEISPIELE 23 TECHNISCHE DATEN 24 HERSTELLERERKLÄRUNGEN 26 ...

Page 3: ... by the user which have not been expressly agreed upon with the party responsible for compliance could void the user s authority to operate the device FOR DEVICES CONNECTED TO A POWER SUPPLY 24 CAUTION If the device s power cable has a protective contact it must be connected to an outlet with a protective ground conductor Never deactivate the power cable s protective ground conductor 25 The mains ...

Page 4: ...mains at least for mains switches or their positions and all those cases where safety is involved WARNING HIGH VOLUME AUDIO PRODUCTS This device is intended for professional use The commercial operation of this device is subject to applicable national regulations and directives for accident prevention As the manufacturer Adam Hall is legally bound to specifically point out potential health risks H...

Page 5: ... expansion card with the same functionality as the Ethernet expansion card plus Dante connectivity Fault relays with terminal block connections per channel pair Universal wide range PFC switching power supply Temperature controlled active cooling with low noise fans in 2 zones PACKAGING CONTENT 1 x LD Systems IPA 424 T or IPA 412 T installation amplifier with pre assembled rack brackets 2 x 6 pole...

Page 6: ...is routed to speaker output CH2 The same also applies to channels 3 and 4 The corresponding level controls work independently of each other PAR Parallel Mode In parallel mode a signal present at line input IN1 is routed to speaker outputs CH1 and CH2 while line input IN2 is deactivated Level controls CH1 and CH2 are used to separately set the volume for the corresponding amplifier channel A signal...

Page 7: ...nd 3 4 The description of the preset and corresponding DIP switch positions can be found in the table below IMAGE DIP switch 3 DIP switch 4 DSP preset CH1 2 CH3 4 Use ON DIP OFF OFF All channels flat Full range speaker ON 1 2 3 4 DIP OFF ON High pass filter on all channels HPF 95Hz LR 24dB Satellite speaker ON DIP ON OFF CH1 CH2 High pass filter HPF 95Hz LR 24dB Satellite speaker CH3 CH4 Low pass ...

Page 8: ... the user manual of the additional remote bus accessories The DIP switch currently has no function DIP SWITCH 4 REM LOCK REMOTE LOCK Move DIP switch 4 to the ON position to lock all of the device s control elements level control DIP switch switch for channel mode and STANDBY button the REM LOCK LED display permanently lights up To unlock the control elements move the DIP switch to the OFF position...

Page 9: ...ases the input dynamic range to 10dB An Ethernet Dante expansion card with the same functionality as the Ethernet expansion card plus Dante connectivity ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON...

Page 10: ...ts the status is displayed on all channels Protect permanently lit The device has encountered a fatal fault To protect the device and connected speaker the device is switched to standby This status is generally displayed on all channels Power supply overtemperature amplifier board overtemperature DC voltage signal at the output DSP error Turn off the device and allow it to cool Disconnect all inpu...

Page 11: ...ON 1 2 3 4 DIP TECHNICAL DATA Item description LDIPA424T LDIPA412T Product type Power amplifier for fixed installations General data Audio channels 4 Output circuit Class D Power supply Wide range switching power supply with PFC power factor correction filter Power supply connector 3 pole power supply socket IEC Auto standby mode Yes Switchable On Off Time to auto standby 20 min without audio inpu...

Page 12: ...e diameter Minimum diameter max AWG of cable cross section is 1 5 mm 16 AWG Maximum diameter min AWG of cable cross section is 3 31 mm 12 AWG Expansion slots Yes For optional Ethernet or Ethernet Dante cards Cooling Passive temperature controlled active two zone cooling with airflow from front to back to the side Operating voltage 100 240 V Mains fuse T10AL 100 120 V T5AL 220 240 V Inrush current ...

Page 13: ... Hz 22 kHz Low Z OUT 3 dB 50 Hz 23 kHz High Z OUT 3 dB Input impedance 40 kOhm symmetrical input design instrumentation speaker Signal to noise ratio 105 dB Low Z SPK OUT 18 dBu CH gain center 0 dB 20 kHz bandwidth A rated 104 dB Low Z SPK OUT 18 dBu CH gain center 0 dB 20 kHz bandwidth A rated Channel crosstalk 83 dB at 1 kHz Common mode rejection CMRR IEC 55 dB 1 kHz Gain Inf to 27dB IN OUT Pote...

Page 14: ... This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause har...

Page 15: ...n Sie alle in Ihrem Land geltenden Entsorgungsgesetze Trennen Sie bei der Entsorgung der Verpackung bitte Kunststoff und Papier bzw Kartonagen voneinander 22 Kunststoffbeutel müssen außer Reichweite von Kindern aufbewahrt werden 23 Sämtliche vom Benutzer vorgenommenen Änderungen und Modifikationen denen die für die Einhaltung der Richtlinien verantwortliche Partei nicht ausdrücklich zugestimmt hat...

Page 16: ... Klemme einer Schutzerde Erdung EIN Strom Um den Anschluss an das Stromnetz anzuzeigen zumindest für Netzschalter oder deren Positionen und alle Fälle in denen die Sicherheit betroffen ist AUS Strom Um die Trennung vom Netz anzuzeigen zumindest für Netzschalter oder deren Positionen und alle Fälle in denen die Sicherheit betroffen ist ACHTUNG HOHE LAUTSTÄRKEN BEI AUDIOPRODUKTEN Dieses Gerät ist fü...

Page 17: ...ichen Funktionalität wie die Ethernet Erweiterungskarte plus Dante Konnektivität Fehlerrelais mit Klemmenblockanschlüssen pro Kanalpaar Universelles Weitbereichs PFC Schaltnetzteil Temperaturgeregelte aktive Kühlung mit geräuscharmen Lüftern in 2 Zonen LIEFERUMFANG 1 x LD Systems IPA 424 T bzw IPA 412 T Installationsverstärker mit vormontierten Rackwinkeln 2 x 6 polige Klemmblöcke für die Audioein...

Page 18: ...nliegt am Lautsprecherausgang CH1 ausgegeben wird und ein Signal das am Line Eingang IN2 anliegt am Laut sprecherausgang CH2 Das Gleiche trifft auch für die Kanäle 3 und 4 zu Die entsprechenden Pegelsteller arbeiten unabhängig voneinander PAR Parallel Modus Im Parallel Modus wird ein Signal das am Line Eingang IN1 anliegt an den Lautsprecherausgängen CH1 und CH2 ausgegeben der Line Eingang IN2 ist...

Page 19: ...nd 4 die DSP Presets für die Lautsprecherausgänge 1 2 und 3 4 Die Beschreibung der Presets und die entsprechenden DIP Schalter Positionen finden Sie in der Tabelle unterhalb BILD DIP Schalter 3 DIP Schalter 4 DSP Preset CH1 2 CH3 4 Anwendung ON DIP OFF OFF Alle Kanäle Flat Fullrange Lautsprecher ON 1 2 3 4 DIP OFF ON High Pass Filter auf allen Kanälen HPF 95Hz LR 24dB Satelliten Lautsprecher ON DI...

Page 20: ...ubehörs Derzeit ist der DIP Schalter ohne Funktion DIP SCHALTER 4 REM LOCK REMOTE LOCK Bringen Sie den DIP Schalter 4 in die Position ON um alle Bedienelemente des Geräts zu sperren Pegelsteller DIP Schalter Schalter für den Kanalmodus und STANDBY Taster die Anzeige LED REM LOCK leuchtet dabei permanent Um die Sperrung der Bedienelemente zu beenden bringen Sie den DIP Schalter in die Position OFF ...

Page 21: ...amikbereich um bis zu 10dB erhöht Eine Ethernet Dante Erweiterungskarte mit der gleichen Funktionalität wie die Ethernet Erweiterungskarte plus Dante Konnektivität ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2...

Page 22: ...t hat einen schwerwiegenden Fehler festgestellt Um das Gerät und die angeschlossenen Lautsprecher zu schüt zen wird das Gerät in den Wartezustand gebracht Dieser Status wird generell in allen Kanälen angezeigt Netzteil Übertemperatur Verstärker Plati ne Übertemperatur Gleichspannungssignal am Ausgang DSP Fehler Schalten Sie das Gerät aus und lassen es abkühlen Ziehen Sie alle Eingangs und Ausgangs...

Page 23: ...CH ENGLISH BELEGUNG DER KLEMMBLOCKANSCHLÜSSE UND SETUP BEISPIELE ON 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 1 2 3 4 DIP ON 2 3 4 DIP ON 1 2 3 4 DIP ...

Page 24: ...ngänge Remote Bus Audioeingang Eingangsanschlüsse 6 Pol Klemmblock Abstand 3 81 mm Remote EIN AUS RJ45 Service Anschluss Micro USB Typ B Ausgänge 4 x spannungsversorgte Lautsprecherausgänge Low Z mindestens 4 Ohm High Z 70 V und 100 V Fehlererken nung 2 x NO NC Relaisausgänge gekoppelt Ausgangsanschlüsse Lautsprecherausgänge 4 Pol Klemmblockanschlüsse Abstand 5 08 mm Fehlerrelais 2 x 3 Pol Klemmbl...

Page 25: ... Gleichstromschutz Mindestlastimpedanz pro Kanal Low Z 4 Ohm einseitig 8 Ohm Bridge 70V 21 Ohm 100V 42 Ohm Low Z 4 Ohm einseitig 8 Ohm Bridge 70V 42 Ohm 100V 84 Ohm Performance Spezifikationen Eingangsempfindlichkeit nominal 5 dBu Sinussignal 1 kHz Gain Max Eingangsübersteuerung nominal 19 dBu Sinussignal 1 kHz Klirrfaktor THD N 0 03 Low Z SPK OUT 18 dBu 20 Hz 20 kHz Intermodulationsverzerrun gen ...

Page 26: ...Personenschäden durch unkontrollierte Abfallentsorgung zu vermeiden Bitte entsorgen Sie dieses Produkt getrennt von anderen Abfällen und führen es zur Förderung nachhaltiger Wirtschaftskreisläufe dem Recycling zu Als Privatkunde erhalten Sie Informationen zu umweltfreundlichen Entsorgungsmöglichkeiten über den Händler bei dem das Produkt erworben wurde oder über die entsprechenden regionalen Behör...

Page 27: ......

Page 28: ...Adam Hall GmbH Adam Hall Str 1 61267 Neu Anspach Germany Phone 49 6081 9419 0 adamhall com ld systems com REV 02 ...

Reviews: