L E C A C H E P R E M I U M W I N E C A B I N E T S
-17-
temperature (HY) differential from 4 degrees to 1 degree. Refer to our “Advanced
Operation” instructions for further instructions how to change the HY differential.
AIR FILTER
All wine cabinets shipped after February 18, 2010, include an air
filter that magnetically attaches to the rear of the cooling unit. To
replace the filter, remove the filter frame from the top of the wine
cabinet (see the image at right), and replace the filter when it
becomes dirty (anywhere from 3 to 9 months depending on the
conditions in your location.
When replacing the filter, the blue fibers should face the
cooling unit, and the white fibers should face away from the
cooling unit.
Replacement filters may be purchased at
www.lecache.com
.
CELLARPRO COOLING UNIT
Factory Settings
The settings on your CellarPro cooling unit have been preset and optimized by the factory,
and it is not necessary to change these settings initially.
If you find that you want to change one or more of the settings, we strongly recommend
that you allow the cooling unit to operate for 14 days before making any changes.
The cooling system is programmed with a 3-Minute Delay at Startup to protect its internal
components.
Temperature
Proper temperatures are maintained by transferring heat from inside wine cellars and
exhausting the heat through the top (top-vent) or rear (rear-vent) of the cooling units.
CellarPro cooling units are designed to turn on when the temperature inside the cellar
exceeds the Minimum Set Point plus the Temperature Differential, and turn off when the
temperature inside the cellar drops below the Minimum Set Point. For example, if the
Summary of Contents for 1400