15
9.
With 7/16 socket wrench, remove the two hex head bolts that attach the
cooling unit to the ceiling of the cellar. Save these bolts! Leave mounting
brackets attached to the cooling unit so that the proper location can be
duplicated with the replacement cooling unit.
PLEASE NOTE: If the nut in the ceiling becomes loose, you will need to use pliers from
the top of the cabinet to hold the nut and keep it from spinning with the bolt.
10.
The cooling unit is now free to remove. Drop front end down, and move side to
side to free from cabinet opening.
CAUTION: Two people may be required to remove the cooling unit, which weighs 48
pounds. Do not let the cooling unit drop on unprotected bottle racks.
TO INSTALL NEW COOLING UNIT
1.
Wait 24 hours before plugging in and operating your CellarPro cooling unit.
2.
Carefully remove the new cooling unit from the packaging. You may reuse this
packaging for shipping or storing the old cooling unit
3.
Remove any materials that have been packed inside the exhaust cavity.
4.
Before installing the cooling unit, make sure it works by plugging it in and
letting it run on a hard, flat surface. Check that cold air is being produced by
the unit.
5.
NEVER turn the cooling unit on its side or upside down
6.
The cooling unit should be plugged into an outlet with a 15-amp circuit
7.
Before installing the cooling unit,
make sure that the exhaust panel
is installed in the correct position.
For
top-vented
cellars,
the
exhaust panel MUST cover the
REAR exhaust vent (see picture at
right). In this configuration, the
cavity on TOP of the cooling unit is
OPEN.
Top Vent Configuration
Panel should be installed on the REAR