17
B.
Replacement Instructions – Rear Vent Units
TOOLS NEEDED:
Phillips screwdriver
7/16" open end wrench or socket
Needlenose pliers
REQUIRED PARTS
Replacement Cooling Unit
Butyl Sealant Tape
REMOVAL OF OLD COOLING UNIT:
1.
Unplug the cooling unit from the wall.
FROM THE REAR OF THE CELLAR
2.
If your cellar comes with a grill(s), remove and discard the grill(s) behind the
cellar. You do not need a grill with the CellarPro cooling unit.
3.
Roll up cord and place in fan cavity at rear of cooling unit. If your cellar came with
a hard-wired light, separate the lamp cord from black and white leads at the back
of the cooling unit.
FROM THE FRONT OF THE CELLAR
4.
Open cellar door and remove all bottles from the top of the rack.
5.
Place a heavy towel or blanket on top of the wine rack for protection.
6.
Remove the light fixture as follows:
- Slide the light left or right, and then unscrew and remove one of the two
mounting brackets that attach the light fixture to the ceiling of the cellar.
- Slide the light fixture off the second mounting bracket.
7.
With 7/16 socket wrench, remove the two hex head bolts that attach the
cooling unit to the ceiling of the cellar. Save these bolts! Leave mounting
brackets attached to the cooling unit so that the proper location can be
duplicated with the replacement cooling unit.
PLEASE NOTE: If the nut in the ceiling becomes loose, you will need to use pliers from
the top of the cabinet to hold the nut and keep it from spinning with the bolt.