V 1.2
12
16)
Calibrate Fluid Sensor (Advanced Option)
:
The fluid sensor located in the fluid bottle cap, must be calibrated for whatever
fluid type is used. It is factory calibrated for LeMaitre’s Global Smoke Fluid, but for
any other fluid should be calibrated accordingly.
Press the UP button begin the calibration procedure
Fully insert the sensor into the full tub of fluid, don’t bother screwing the cap on
though.
Press the UP button once more.
The machine will prompt the user to pull the sensor fully out of the fluid and drain
for 30 seconds.
Once the 30 seconds are up and it says complete, press the UP button again.
Calibration is complete, screw the bottle cap into place.
17)
Fluid Level (Advanced Option)
:
Display what the current fluid level is at. A value of 0-100%.
NOTE: After calibration, and with a full bottle of fluid, this should show 100%. If
not, please redo the calibration procedure.
18)
Version Info (Advanced Option)
:
Displays version information. This might be asked for during support requests, and
to see if there are any firmware updates available for the machine.
19)
Runtime stats in hours (Advanced Option)
:
RT =Uptime of the machine
ST = Smoke time, how long the machine has been pumping smoke
20)
Reset to default (Advanced Option)
:
In the event of a forgotten AP password for the Web Server Interface, or similar
issue, it is possible to reset the machine back to its shipped factory settings.
21)
Wi-Fi/Ethernet Status (Advanced Option)
:
This shows information on the status of the Wi-Fi processor.
22)
DMX Analyser (Advanced Option)
:
The G300-Smart has a built in DMX analyser. Press the UP and DOWN buttons to
view the signal BREAK and MAB times, the refresh rate and also number of bytes in
the DMX packet. This can be helpful to diagnose any DMX signal issues.
23)
Machine Serial Number (Advanced Option)
:
The unique serial number of the machine can be seen here.
This may be required for any service/support requests as well.