V 1.2
14
0-10V Modes
When operating the machine using the 0-10V interface, there are 3 different modes that can be
used. These modes operate in the exact same fashion the DMX modes, with the only exception
being there is no Mode 3 (manual mode).
Mode 0:
This mode operates the machine using the flow level input only.
Once a value larger than a few hundred mV is seen, operation is started. The power output
(Freezefog) is energized for the set predelay time, and once the predelay time has elapsed, the
machine will output smoke at a level set on the channel, up to 100%. To turn off operation, set
the input to 0V.
Mode 1:
This mode operates the machine using the Smoke On/Off input only. It uses this input purely as
an on/off switch, and utilises all the pre-programmed timing settings and flow level set on the
machine.
Mode 2:
This mode operates the machine using both inputs. It utilises the Flow Level input to set the flow
level, and the Smoke On/Off input to start/stop operation. For Freezefog operation, it utilises the
programmed predelay timing setting. This is the only timing value that is used.
0-10V Pin Functions:
Pin 1 – Common
Pin 2 – Smoke On
Pin 3 – Flow