V 1.2
9
2)
Flashing during operation, but not actually outputting smoke (in an interval time for
example)
3)
Solidly on when outputting smoke
Wi-Fi/LAN – Will illuminate when the unit receives a control command via the Wi-Fi/LAN
interface. Once illuminated, it will also quickly flash to indicate successful communications
between the G300 Smart and the wireless/wired controlling device.
Buttons
MENU
– The G300-Smart has a simple, single direction, numbered, circular menu. The MENU
button is used to enter the menu, and each press will cycle the menu one setting further. Once the
end of the menu is reached, it will leave the menu and return to the operating screen. Holding
down the MENU button once in the menu, will also leave the menu and return back to the
operating screen.
DOWN
– The DOWN button is only used to change/modify corresponding menu settings down. It
has no effect on the menu position like the MENU button does.
UP
– Similarly, the UP button is only used to change/modify corresponding menu settings up. It
has no effect on the menu position like the MENU button does.
Output Control Knob
The output control knob is used to set the desired flow level (1-100%) of the smoke output in
manual mode, and specific modes in 0-10V and DMX operation.
SMOKE switch
The smoke switch is used to start/stop the operation of the smoke machine in manual mode.
It also can override and cancel any control via the Wi-Fi/Ethernet interfaces, and hence should be
switched to the OFF position if those methods of control are desired.