4
1.
During use this machine generates condensation. After use the LSX should be drained via
the drain valve.
CAUTION
: This may cause the floor to become very slippery. This may also inhibit the
performance of the LSX unit.
2.
This unit requires a 15 amp circuit to run properly. The use of any extension cords or shared
circuit is strongly not recommended.
3.
It is essential that Le Maitre’s Genuine LSX Molecular Fluid is used in the Fog Machine to
achieve optimum effect.
4.
The LSX unit is controlled by a user-friendly panel. When the system switch is in the ‘On’
position and illuminated, power is established to the LSX unit. A ‘green led’ is provided to
indicate the compressor is operating.
5.
An Automatic Reset Low Pressure Switch is provided as protection against compressor
damage. If the Low Pressure Switch has been activated the ‘Red’ LED will illuminate (the ‘Green’
LED will not be illuminated).
6.
The Variable Fan Control regulates Fog Density Output. Some experimenting will produce
various effects. An OFF position is provided on this control. It is not recommended that this
control be left in the off position as this will eventually result in activation of the Low Pressure
Switch and cause a freeze up condition.