15
6. Service and Maintenance
(6) Pump cable
(8) Fluid
tubing
(9)
Tubing
spout
(7) Vaporizer
(10) Male
connector strip
Connectors for
pumping cable
6.1 Changing the Vaporizer
The micro vaporizer especially developed for the TINY-FOGGER has a limited
working life. Depending on application duration, you can achieve between 2,000
and 5,000 fogging cycles. After these the fogging performance declines con-
siderably and the vaporizer must be changed.
6.1.1 Removal of the Vaporizer
• Separate the TINY-FOGGER from the battery (take off the battery clip),
• Unscrew the two screws (5) with a suitable screwdriver (No. 1. Phillips),
• Take off the casing cover,
• Unplug the connector for pump cable (6),
• Now you can slide out the vaporizer (7) upwards,
• Remove the blue fluid tubing (8) from tubing spout (9) of the vaporizer. In
case the tubing does not come off, you can pull it down with a pair of pliers or
a similar tool,
• Clean the interior of the unit with an absorbant, fluff-free cloth.